2005GutOpen access

Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study

Juliette Foucher

Open full text 1,285 citations

Abstract

BACKGROUND: Transient elastography (FibroScan) is a new, non-invasive, rapid, and reproducible method allowing evaluation of liver fibrosis by measurement of liver stiffness. In cirrhotic patients, liver stiffness measurements range from 12.5 to 75.5 kPa. However, the clinical relevance of these values is unknown. The aim of this prospective study was to evaluate the accuracy of liver stiffness measurement for the detection of cirrhosis in patients with chronic liver disease. METHODS: A total of 711 patients with chronic liver disease were studied. Aetiologies of chronic liver diseases were hepatitis C virus or hepatitis B virus infection, alcohol, non-alcoholic steatohepatitis, other, or a combination of the above aetiologies. Liver fibrosis was evaluated according to the METAVIR score. RESULTS: Stiffness was significantly correlated with fibrosis stage (r=0.73, p<0.0001). Areas under the receiver operating characteristic curve (95% confidence interval) were 0.80 (0.75-0.84) for patients with significant fibrosis (F>2), 0.90 (0.86-0.93) for patients with severe fibrosis (F3), and 0.96 (0.94-0.98) for patients with cirrhosis. Using a cut off value of 17.6 kPa, patients with cirrhosis were detected with a positive predictive value and a negative predictive value (NPV) of 90%. Liver stiffness was significantly correlated with clinical, biological, and morphological parameters of liver disease. With an NPV>90%, the cut off values for the presence of oesophageal varices stage 2/3, cirrhosis Child-Pugh B or C, past history of ascites, hepatocellular carcinoma, and oesophageal bleeding were 27.5, 37.5, 49.1, 53.7, and 62.7 kPa, respectively. CONCLUSION: Transient elastography is a promising non-invasive method for detection of cirrhosis in patients with chronic liver disease. Its use for the follow up and management of these patients could be of great interest and should be evaluated further.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Transient elastography (FibroScan) is a new, non-invasive, rapid, and reproducible method allowing evaluation of liver fibrosis by measurement of liver stiffness. In cirrhotic patients, liver stiffness measurements range from 12.5 to 75.5 kPa. However, the clinical relevance of these values is unknown. The aim of this prospective study was to evaluate the accuracy of liver stiffness measurement for the detection of cirrhosis in patients with chronic liver disease. METHODS: A total of 711 patients with chronic liver disease were studied. Aetiologies of chronic liver diseases were hepatitis C virus or hepatitis B virus infection, alcohol, non-alcoholic steatohepatitis, other, or a combination of the above aetiologies. Liver fibrosis was evaluated according to the METAVIR score. RESULTS: Stiffness was significantly correlated with fibrosis stage (r=0.73, p<0.0001). Areas under the receiver operating characteristic curve (95% confidence interval) were 0.80 (0.75-0.84) for patients with significant fibrosis (F>2), 0.90 (0.86-0.93) for patients with severe fibrosis (F3), and 0.96 (0.94-0.98) for patients with cirrhosis. Using a cut off value of 17.6 kPa, patients with cirrhosis were detected with a positive predictive value and a negative predictive value (NPV) of 90%. Liver stiffness was significantly correlated with clinical, biological, and morphological parameters of liver disease. With an NPV>90%, the cut off values for the presence of oesophageal varices stage 2/3, cirrhosis Child-Pugh B or C, past history of ascites, hepatocellular carcinoma, and oesophageal bleeding were 27.5, 37.5, 49.1, 53.7, and 62.7 kPa, respectively. CONCLUSION: Transient elastography is a promising non-invasive method for detection of cirrhosis in patients with chronic liver disease. Its use for the follow up and management of these patients could be of great interest and should be evaluated further.

Why it matters

OpenAlex reports 1285 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Transient elastography (FibroScan) is a new, non-invasive, rapid, and reproducible method allowing evaluation of liver fibrosis by measurement of liver stiffness. In cirrhotic patients, liver stiffness measurements range from 12.5 to 75.5 kPa. However, the clinical relevance of these values is unknown. The aim of this prospective study was to evaluate the accuracy of liver stiffness measurement for the detection of cirrhosis in patients with chronic liver disease. METHODS: A total of 711 patients with chronic liver disease were studied. Aetiologies of chronic liver diseases were hepatitis C virus or hepatitis B virus infection, alcohol, non-alcoholic steatohepatitis, other, or a combination of the above aetiologies. Liver fibrosis was evaluated according to the METAVIR score. RESULTS: Stiffness was significantly correlated with fibrosis stage (r=0.73, p<0.0001). Areas under the receiver operating characteristic curve (95% confidence interval) were 0.80 (0.75-0.84) for patients with significant fibrosis (F>2), 0.90 (0.86-0.93) for patients with severe fibrosis (F3), and 0.96 (0.94-0.98) for patients with cirrhosis. Using a cut off value of 17.6 kPa, patients with cirrhosis were detected with a positive predictive value and a negative predictive value (NPV) of 90%. Liver stiffness was significantly correlated with clinical, biological, and morphological parameters of liver disease. With an NPV>90%, the cut off values for the presence of oesophageal varices stage 2/3, cirrhosis Child-Pugh B or C, past history of ascites, hepatocellular carcinoma, and oesophageal bleeding were 27.5, 37.5, 49.1, 53.7, and 62.7 kPa, respectively. CONCLUSION: Transient elastography is a promising non-invasive method for detection of cirrhosis in patients with chronic liver disease. Its use for the follow up and management of these patients could be of great interest and should be evaluated further.

Key concepts: Transient elastography, Medicine, Cirrhosis, Gastroenterology, Internal medicine, Steatohepatitis, Chronic liver disease, Liver disease

Related papers

Back to paper searchBrowse research topicsOriginal source
Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study — Research Paper | ScholarLens