2006Japanese Journal of Applied PhysicsRequires access

Nondestructive Measurement of Hexavalent Chromium in Chromate Conversion Coatings Using X-ray Absorption Near Edge Structure

Kenji Nomura, N. Awaji

Open publisher page 6 citations

Abstract

We developed a nondestructive evaluation technique of hexavalent chromium (Cr 6+ ) in chromate conversion coatings on the basis of a pre-edge peak that appeared in an X-ray absorption near-edge structure (XANES) measured at the SPring-8 synchrotron radiation facility BL16B2. By applying this technique, a percentage of the hexavalent chromium in the actual chromate conversion coating has been evaluated. Furthermore, to determine the depth distribution of hexavalent chromium in the coating, grazing incidence X-ray fluorescence (GIXRF) measurement has been performed. From the data analysis, we found that hexavalent chromium concentration is decreased around the surface region of the coating.

About this research paper

What this paper is about

We developed a nondestructive evaluation technique of hexavalent chromium (Cr 6+ ) in chromate conversion coatings on the basis of a pre-edge peak that appeared in an X-ray absorption near-edge structure (XANES) measured at the SPring-8 synchrotron radiation facility BL16B2. By applying this technique, a percentage of the hexavalent chromium in the actual chromate conversion coating has been evaluated. Furthermore, to determine the depth distribution of hexavalent chromium in the coating, grazing incidence X-ray fluorescence (GIXRF) measurement has been performed. From the data analysis, we found that hexavalent chromium concentration is decreased around the surface region of the coating.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We developed a nondestructive evaluation technique of hexavalent chromium (Cr 6+ ) in chromate conversion coatings on the basis of a pre-edge peak that appeared in an X-ray absorption near-edge structure (XANES) measured at the SPring-8 synchrotron radiation facility BL16B2. By applying this technique, a percentage of the hexavalent chromium in the actual chromate conversion coating has been evaluated. Furthermore, to determine the depth distribution of hexavalent chromium in the coating, grazing incidence X-ray fluorescence (GIXRF) measurement has been performed. From the data analysis, we found that hexavalent chromium concentration is decreased around the surface region of the coating.

Key concepts: Hexavalent chromium, Chromate conversion coating, Coating, XANES, Chromium, Materials science, Synchrotron radiation, Absorption edge

Related papers

Back to paper searchBrowse research topicsOriginal source
Nondestructive Measurement of Hexavalent Chromium in Chromate Conversion Coatings Using X-ray Absorption Near Edge Structure — Research Paper | ScholarLens