Validation of hand‐held bioelectrical impedance analysis with magnetic resonance imaging for the assessment of body composition in overweight women

Krista A Varady, Sylvia Santosa, Peter J.H. Jones

Open publisher page 16 citations

Abstract

Methods of assessing body composition suitable for use in clinical trials should be accurate, reliable, and easy to perform. One such technique routinely implemented is hand-held bioelectrical impedance analysis (BIA). The validity of this method, however, in body composition assessment of overweight women is not known. The aim of this study was to validate the hand-held BIA technique with magnetic resonance imaging (MRI) for the assessment of body composition in overweight women. Fat mass, percent fat mass, fat-free mass, and percent fat-free mass values estimated by hand-held BIA were compared to those measured by MRI. Thirty-one Caucasian women (50.1 +/- 8.2 years, body mass index of 26.9 +/- 3.1 kg/m(2)) participated in the study. BIA measurements were highly reproducible (technical error (TE) was 0.06 +/- 0.07 kg for fat mass and 0.08 +/- 0.11% for percent fat mass), but were significantly different (P < 0.0001) for each body composition parameter when compared to MRI. BIA underestimated fat mass by 2.3 +/- 3.3 kg and percent fat mass by 5.6 +/- 3.9%. Likewise, BIA overestimated fat free mass by 7.4 +/- 2.7 kg and percent fat free mass by 5.6 +/- 3.2%. No relationship between the bias and the mean of the two measurements was noted suggesting that bias is not related to measurement size. Although hand-held BIA gives reproducible findings, the bias noted for all body composition parameters puts into question the validity of this regional impedance device for use in clinical trials in overweight women.

About this research paper

What this paper is about

Methods of assessing body composition suitable for use in clinical trials should be accurate, reliable, and easy to perform. One such technique routinely implemented is hand-held bioelectrical impedance analysis (BIA). The validity of this method, however, in body composition assessment of overweight women is not known. The aim of this study was to validate the hand-held BIA technique with magnetic resonance imaging (MRI) for the assessment of body composition in overweight women. Fat mass, percent fat mass, fat-free mass, and percent fat-free mass values estimated by hand-held BIA were compared to those measured by MRI. Thirty-one Caucasian women (50.1 +/- 8.2 years, body mass index of 26.9 +/- 3.1 kg/m(2)) participated in the study. BIA measurements were highly reproducible (technical error (TE) was 0.06 +/- 0.07 kg for fat mass and 0.08 +/- 0.11% for percent fat mass), but were significantly different (P < 0.0001) for each body composition parameter when compared to MRI. BIA underestimated fat mass by 2.3 +/- 3.3 kg and percent fat mass by 5.6 +/- 3.9%. Likewise, BIA overestimated fat free mass by 7.4 +/- 2.7 kg and percent fat free mass by 5.6 +/- 3.2%. No relationship between the bias and the mean of the two measurements was noted suggesting that bias is not related to measurement size. Although hand-held BIA gives reproducible findings, the bias noted for all body composition parameters puts into question the validity of this regional impedance device for use in clinical trials in overweight women.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Methods of assessing body composition suitable for use in clinical trials should be accurate, reliable, and easy to perform. One such technique routinely implemented is hand-held bioelectrical impedance analysis (BIA). The validity of this method, however, in body composition assessment of overweight women is not known. The aim of this study was to validate the hand-held BIA technique with magnetic resonance imaging (MRI) for the assessment of body composition in overweight women. Fat mass, percent fat mass, fat-free mass, and percent fat-free mass values estimated by hand-held BIA were compared to those measured by MRI. Thirty-one Caucasian women (50.1 +/- 8.2 years, body mass index of 26.9 +/- 3.1 kg/m(2)) participated in the study. BIA measurements were highly reproducible (technical error (TE) was 0.06 +/- 0.07 kg for fat mass and 0.08 +/- 0.11% for percent fat mass), but were significantly different (P < 0.0001) for each body composition parameter when compared to MRI. BIA underestimated fat mass by 2.3 +/- 3.3 kg and percent fat mass by 5.6 +/- 3.9%. Likewise, BIA overestimated fat free mass by 7.4 +/- 2.7 kg and percent fat free mass by 5.6 +/- 3.2%. No relationship between the bias and the mean of the two measurements was noted suggesting that bias is not related to measurement size. Although hand-held BIA gives reproducible findings, the bias noted for all body composition parameters puts into question the validity of this regional impedance device for use in clinical trials in overweight women.

Key concepts: Bioelectrical impedance analysis, Overweight, Fat free mass, Magnetic resonance imaging, Fat mass, Body mass index, Medicine, Composition (language)