Elimination of quinolone antibiotic carryover through use of antibiotic-removal beads
Richard A. Zabinski, Alison J. Larsson, Karla J. Walker, Susan S. Gilliland, John C. Rotschafer
Abstract
Richard A. Zabinski, Alison J. Larsson, Karla J. Walker, Susan S. Gilliland, John C. Rotschafer
Abstract
To prove the utility of antibiotic-removal beads in separating antibiotics from bacterial samples, Escherichia coli ATCC 25922 was exposed to five separate quinolones before and after each was exposed to antibiotic-removal beads. Plates treated with antibiotic solutions that were exposed to beads demonstrated antibiotic removal, and plates treated with antibiotic solutions that were not exposed to beads demonstrated antibiotic carryover. After exposure to beads, fluoroquinolone concentrations decreased from 5 micrograms/ml to 0.14 micrograms/ml (ciprofloxacin), 0.04 micrograms/ml (temafloxacin), < 0.01 microgram/ml (ofloxacin), < 0.01 microgram/ml (sparfloxacin), and 0.02 micrograms/ml (clinafloxacin). These data indicate that antibiotic carryover can be successfully circumvented through the use of antibiotic-removal beads.
OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
To prove the utility of antibiotic-removal beads in separating antibiotics from bacterial samples, Escherichia coli ATCC 25922 was exposed to five separate quinolones before and after each was exposed to antibiotic-removal beads. Plates treated with antibiotic solutions that were exposed to beads demonstrated antibiotic removal, and plates treated with antibiotic solutions that were not exposed to beads demonstrated antibiotic carryover. After exposure to beads, fluoroquinolone concentrations decreased from 5 micrograms/ml to 0.14 micrograms/ml (ciprofloxacin), 0.04 micrograms/ml (temafloxacin), < 0.01 microgram/ml (ofloxacin), < 0.01 microgram/ml (sparfloxacin), and 0.02 micrograms/ml (clinafloxacin). These data indicate that antibiotic carryover can be successfully circumvented through the use of antibiotic-removal beads.
Key concepts: Ofloxacin, Antibiotics, Sparfloxacin, Ciprofloxacin, Quinolone, Microbiology, Antibacterial agent, Chemistry