1993Antimicrobial Agents and ChemotherapyOpen access

Elimination of quinolone antibiotic carryover through use of antibiotic-removal beads

Richard A. Zabinski, Alison J. Larsson, Karla J. Walker, Susan S. Gilliland, John C. Rotschafer

Open full text 26 citations

Abstract

To prove the utility of antibiotic-removal beads in separating antibiotics from bacterial samples, Escherichia coli ATCC 25922 was exposed to five separate quinolones before and after each was exposed to antibiotic-removal beads. Plates treated with antibiotic solutions that were exposed to beads demonstrated antibiotic removal, and plates treated with antibiotic solutions that were not exposed to beads demonstrated antibiotic carryover. After exposure to beads, fluoroquinolone concentrations decreased from 5 micrograms/ml to 0.14 micrograms/ml (ciprofloxacin), 0.04 micrograms/ml (temafloxacin), < 0.01 microgram/ml (ofloxacin), < 0.01 microgram/ml (sparfloxacin), and 0.02 micrograms/ml (clinafloxacin). These data indicate that antibiotic carryover can be successfully circumvented through the use of antibiotic-removal beads.

About this research paper

What this paper is about

To prove the utility of antibiotic-removal beads in separating antibiotics from bacterial samples, Escherichia coli ATCC 25922 was exposed to five separate quinolones before and after each was exposed to antibiotic-removal beads. Plates treated with antibiotic solutions that were exposed to beads demonstrated antibiotic removal, and plates treated with antibiotic solutions that were not exposed to beads demonstrated antibiotic carryover. After exposure to beads, fluoroquinolone concentrations decreased from 5 micrograms/ml to 0.14 micrograms/ml (ciprofloxacin), 0.04 micrograms/ml (temafloxacin), < 0.01 microgram/ml (ofloxacin), < 0.01 microgram/ml (sparfloxacin), and 0.02 micrograms/ml (clinafloxacin). These data indicate that antibiotic carryover can be successfully circumvented through the use of antibiotic-removal beads.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To prove the utility of antibiotic-removal beads in separating antibiotics from bacterial samples, Escherichia coli ATCC 25922 was exposed to five separate quinolones before and after each was exposed to antibiotic-removal beads. Plates treated with antibiotic solutions that were exposed to beads demonstrated antibiotic removal, and plates treated with antibiotic solutions that were not exposed to beads demonstrated antibiotic carryover. After exposure to beads, fluoroquinolone concentrations decreased from 5 micrograms/ml to 0.14 micrograms/ml (ciprofloxacin), 0.04 micrograms/ml (temafloxacin), < 0.01 microgram/ml (ofloxacin), < 0.01 microgram/ml (sparfloxacin), and 0.02 micrograms/ml (clinafloxacin). These data indicate that antibiotic carryover can be successfully circumvented through the use of antibiotic-removal beads.

Key concepts: Ofloxacin, Antibiotics, Sparfloxacin, Ciprofloxacin, Quinolone, Microbiology, Antibacterial agent, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Elimination of quinolone antibiotic carryover through use of antibiotic-removal beads — Research Paper | ScholarLens