1991International Journal of Environmental & Analytical ChemistryRequires access

Fluorimetric Determination of Mercury(II) Based on its Reaction with Iodide and Triphenylmethane Compounds

Vassilios Kabasakalis, R. Tsitouridou, C. A. Alexiades

Open publisher page 4 citations

Abstract

A fluorimetric method for the determination of Hg2+ (5–100 ppb) was developed based on the reaction between triphenylmethane cations (Brilliant green, Malachite green and Crystal violet) and tetraiodo-mercurate(II). This reactioon gives ion-associated complexes with strong fluoresence at 521 nm after excitation at 256 nm. Optimum concentrations for Brilliant green, Malachite green and Crystal violet were 15, 10 and 2 mg/l, respectively. The optimum pH for complex formation was 3.0 for Brilliant green and Malachite green, and 2.0 for Crystal violet. The detection limit for the method defined as 3 σ [sgrave] was found to be 0.72 μg/1 of Hg2+. Ions that interfere in the determination of mercury by the proposed method are Ag(I), Pt(II), Cd(II), Bi(III) and Ti(IV). Titanium(IV), Ag(I) and Bi(III) can be masked whereas the interference of Pt(II) and Cd(II) cannot be overcome as yet.

About this research paper

What this paper is about

A fluorimetric method for the determination of Hg2+ (5–100 ppb) was developed based on the reaction between triphenylmethane cations (Brilliant green, Malachite green and Crystal violet) and tetraiodo-mercurate(II). This reactioon gives ion-associated complexes with strong fluoresence at 521 nm after excitation at 256 nm. Optimum concentrations for Brilliant green, Malachite green and Crystal violet were 15, 10 and 2 mg/l, respectively. The optimum pH for complex formation was 3.0 for Brilliant green and Malachite green, and 2.0 for Crystal violet. The detection limit for the method defined as 3 σ [sgrave] was found to be 0.72 μg/1 of Hg2+. Ions that interfere in the determination of mercury by the proposed method are Ag(I), Pt(II), Cd(II), Bi(III) and Ti(IV). Titanium(IV), Ag(I) and Bi(III) can be masked whereas the interference of Pt(II) and Cd(II) cannot be overcome as yet.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A fluorimetric method for the determination of Hg2+ (5–100 ppb) was developed based on the reaction between triphenylmethane cations (Brilliant green, Malachite green and Crystal violet) and tetraiodo-mercurate(II). This reactioon gives ion-associated complexes with strong fluoresence at 521 nm after excitation at 256 nm. Optimum concentrations for Brilliant green, Malachite green and Crystal violet were 15, 10 and 2 mg/l, respectively. The optimum pH for complex formation was 3.0 for Brilliant green and Malachite green, and 2.0 for Crystal violet. The detection limit for the method defined as 3 σ [sgrave] was found to be 0.72 μg/1 of Hg2+. Ions that interfere in the determination of mercury by the proposed method are Ag(I), Pt(II), Cd(II), Bi(III) and Ti(IV). Titanium(IV), Ag(I) and Bi(III) can be masked whereas the interference of Pt(II) and Cd(II) cannot be overcome as yet.

Key concepts: Malachite green, Triphenylmethane, Crystal violet, Brilliant green, Triarylmethane dye, Chemistry, Mercury (programming language), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Fluorimetric Determination of Mercury(II) Based on its Reaction with Iodide and Triphenylmethane Compounds — Research Paper | ScholarLens