Three-dimensional radiochromic film dosimetry of proton clinical beams using a gafchromic EBT2 film array
Joo‐Young Kim, Myonggeun Yoon, S. Kim, D. Shin, S. B. Lee, Young Kyung Lim, Dong Wook Kim, S. Y. Park
Abstract
Joo‐Young Kim, Myonggeun Yoon, S. Kim, D. Shin, S. B. Lee, Young Kyung Lim, Dong Wook Kim, S. Y. Park
Abstract
In this work, three-dimensional (3D) film-based proton beam measurements were used for the first time to verify the patient-specific radiation dose distribution, beam range and compensator shape. Three passively scattered proton beams and one uniform scanning proton beam were directed onto an acrylic phantom with inserted Gafchromic EBT films. The average gamma index for a comparison of the dose distributions was less than one for 97.2 % of all pixels from the passively scattered proton beams and 98.1 % of all pixels for the uniform scanning proton beams, with a 3 % dose and a 3 mm distance-to-dose agreement tolerance limit. The results also showed that the average percentage of points within the acceptance criteria for proton beam ranges was 94.6 % for the passively scattered proton beams. Both the dose distribution and the proton beam range determined by the 3D EBT film measurement agreed well with the planning system values.
OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this work, three-dimensional (3D) film-based proton beam measurements were used for the first time to verify the patient-specific radiation dose distribution, beam range and compensator shape. Three passively scattered proton beams and one uniform scanning proton beam were directed onto an acrylic phantom with inserted Gafchromic EBT films. The average gamma index for a comparison of the dose distributions was less than one for 97.2 % of all pixels from the passively scattered proton beams and 98.1 % of all pixels for the uniform scanning proton beams, with a 3 % dose and a 3 mm distance-to-dose agreement tolerance limit. The results also showed that the average percentage of points within the acceptance criteria for proton beam ranges was 94.6 % for the passively scattered proton beams. Both the dose distribution and the proton beam range determined by the 3D EBT film measurement agreed well with the planning system values.
Key concepts: Dosimetry, Materials science, Proton, Optics, Medical physics, Nuclear medicine, Physics, Nuclear physics