1962OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Requires access

USE OF THE METHOD OF AMPEROMETRIC TITRATION WITH TWO INDICATOR ELECTRODES FOR THE VOLUMETRIC DETERMINATION OF URANIUM

N.I. Udal'tsova

Open publisher page 0 citations

Abstract

The method of amperometric titration with the use of two indicator electrodes--dead stop end point was used for titration of uranium(IV) with a number of oxidizers: (NH/sub 4/VO/sub 3/, Ce(SO/sub 4/)/sub 2/, K/sub 2/Cr/sub 2/ O/sub 7/, KMnO/sub 4/, and NH/sub 4/Fe(SO /sub 4/)/sub 2/. The method permits the determination of smaller quantities of uranium (down to about 1.5 gamma /ml) with higher accuracy than the ordinary method of amperometric titration or a potentiometric method. (auth)

About this research paper

What this paper is about

The method of amperometric titration with the use of two indicator electrodes--dead stop end point was used for titration of uranium(IV) with a number of oxidizers: (NH/sub 4/VO/sub 3/, Ce(SO/sub 4/)/sub 2/, K/sub 2/Cr/sub 2/ O/sub 7/, KMnO/sub 4/, and NH/sub 4/Fe(SO /sub 4/)/sub 2/. The method permits the determination of smaller quantities of uranium (down to about 1.5 gamma /ml) with higher accuracy than the ordinary method of amperometric titration or a potentiometric method. (auth)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The method of amperometric titration with the use of two indicator electrodes--dead stop end point was used for titration of uranium(IV) with a number of oxidizers: (NH/sub 4/VO/sub 3/, Ce(SO/sub 4/)/sub 2/, K/sub 2/Cr/sub 2/ O/sub 7/, KMnO/sub 4/, and NH/sub 4/Fe(SO /sub 4/)/sub 2/. The method permits the determination of smaller quantities of uranium (down to about 1.5 gamma /ml) with higher accuracy than the ordinary method of amperometric titration or a potentiometric method. (auth)

Key concepts: Amperometric titration, Potentiometric titration, Amperometry, Titration, Uranium, Chemistry, Analytical Chemistry (journal), Gran plot

Related papers

Back to paper searchBrowse research topicsOriginal source
USE OF THE METHOD OF AMPEROMETRIC TITRATION WITH TWO INDICATOR ELECTRODES FOR THE VOLUMETRIC DETERMINATION OF URANIUM — Research Paper | ScholarLens