2014Unpublished venueRequires access

Investigation of R152a/R22 mixture in air conditioning system

S. Vandaarkuzhali, R. Elansezhian

Open publisher page 0 citations

Abstract

In domestic air conditioning system the most widely used refrigerant is R22 has a high Global Warming Potential (GWP) of 1700 and a ozone depletion potential (ODP) of 0.05. Hence a new solution for this refrigerant is to be identified. R152a is identified as an alternative to R12 and R22 refrigerants. In this paper an experimental investigation was made to reduce the usage of R22 with the Hydrocarbon Refrigerant mixtures (HCM) of R22 and R152a refrigerants in the ratio of 30:70, 50:50, and 70:30 by mass. Experiments were conducted by continuous running tests under an ambient temperature of 32°C. The overall performance of the system proved that the HCM could be a long term substitute for R22 (chlorodifluoromethane).

About this research paper

What this paper is about

In domestic air conditioning system the most widely used refrigerant is R22 has a high Global Warming Potential (GWP) of 1700 and a ozone depletion potential (ODP) of 0.05. Hence a new solution for this refrigerant is to be identified. R152a is identified as an alternative to R12 and R22 refrigerants. In this paper an experimental investigation was made to reduce the usage of R22 with the Hydrocarbon Refrigerant mixtures (HCM) of R22 and R152a refrigerants in the ratio of 30:70, 50:50, and 70:30 by mass. Experiments were conducted by continuous running tests under an ambient temperature of 32°C. The overall performance of the system proved that the HCM could be a long term substitute for R22 (chlorodifluoromethane).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In domestic air conditioning system the most widely used refrigerant is R22 has a high Global Warming Potential (GWP) of 1700 and a ozone depletion potential (ODP) of 0.05. Hence a new solution for this refrigerant is to be identified. R152a is identified as an alternative to R12 and R22 refrigerants. In this paper an experimental investigation was made to reduce the usage of R22 with the Hydrocarbon Refrigerant mixtures (HCM) of R22 and R152a refrigerants in the ratio of 30:70, 50:50, and 70:30 by mass. Experiments were conducted by continuous running tests under an ambient temperature of 32°C. The overall performance of the system proved that the HCM could be a long term substitute for R22 (chlorodifluoromethane).

Key concepts: Refrigerant, Air conditioning, Global-warming potential, Environmental science, Waste management, Heat exchanger, Engineering, Greenhouse gas

Related papers

Back to paper searchBrowse research topicsOriginal source
Investigation of R152a/R22 mixture in air conditioning system — Research Paper | ScholarLens