2012Unpublished venueRequires access

Improved control strategy of wind turbine with DFIG for Low Voltage Ride Through capability

Sriram Chandrasekaran, C. Rossi, D. Casadei, Angelo Tani

Open publisher page 13 citations

Abstract

This paper deals with a protection and control strategy to enhance the low voltage ride through capability of a wind turbine driven doubly fed induction generator (DFIG). As the wind power penetration continues to increase, wind turbines are required to provide Low Voltage Ride-Through (LVRT) capability. Crowbars are commonly used to protect the power converters during voltage dips and their main drawback is that the DFIG absorbs reactive power from the grid during grid faults. According to emergency grid code requirements, wind farms should have the ability to stay connected and continue generation under external voltage failure conditions, that is, wind turbines have to keep in connection with grid and own continue reactive power supply. This paper proposes a hysteresis current control strategy for the crowbar protection and a reactive power control to satisfy the grid code requirements. Consequently, the dynamic model of double fed wind turbines is established to study the transient behavior of DFIG. Simulation results are presented to show the effectiveness of the proposed control scheme.

About this research paper

What this paper is about

This paper deals with a protection and control strategy to enhance the low voltage ride through capability of a wind turbine driven doubly fed induction generator (DFIG). As the wind power penetration continues to increase, wind turbines are required to provide Low Voltage Ride-Through (LVRT) capability. Crowbars are commonly used to protect the power converters during voltage dips and their main drawback is that the DFIG absorbs reactive power from the grid during grid faults. According to emergency grid code requirements, wind farms should have the ability to stay connected and continue generation under external voltage failure conditions, that is, wind turbines have to keep in connection with grid and own continue reactive power supply. This paper proposes a hysteresis current control strategy for the crowbar protection and a reactive power control to satisfy the grid code requirements. Consequently, the dynamic model of double fed wind turbines is established to study the transient behavior of DFIG. Simulation results are presented to show the effectiveness of the proposed control scheme.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper deals with a protection and control strategy to enhance the low voltage ride through capability of a wind turbine driven doubly fed induction generator (DFIG). As the wind power penetration continues to increase, wind turbines are required to provide Low Voltage Ride-Through (LVRT) capability. Crowbars are commonly used to protect the power converters during voltage dips and their main drawback is that the DFIG absorbs reactive power from the grid during grid faults. According to emergency grid code requirements, wind farms should have the ability to stay connected and continue generation under external voltage failure conditions, that is, wind turbines have to keep in connection with grid and own continue reactive power supply. This paper proposes a hysteresis current control strategy for the crowbar protection and a reactive power control to satisfy the grid code requirements. Consequently, the dynamic model of double fed wind turbines is established to study the transient behavior of DFIG. Simulation results are presented to show the effectiveness of the proposed control scheme.

Key concepts: Low voltage ride through, Crowbar, Grid code, Wind power, AC power, Turbine, Grid, Control theory (sociology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Improved control strategy of wind turbine with DFIG for Low Voltage Ride Through capability — Research Paper | ScholarLens