2003Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

Development and design of a new spectral imaging system for melanoma research

Mary C. Haddock, Jeffrey C. Bamber, R.J. Ott

Open publisher page 2 citations

Abstract

There is currently a search for an automated, objective and non-invasive system that would accurately diagnose pigmented skin tumours. Systems that measure either the spatial or the spectral characteristics of light reflected from the skin have shown promise for this purpose but only a few studies have combined spatial and spectral information. We plan to study this and consequently need to construct a cost-effective research spectral imaging system but the design will require a compromise between spatial and spectral information. Here, the effect, on diagnostic accuracy, of reducing the spectral resolution of spectrophotometry data was studied. Also studied was the effect of reducing the spectral range to that of the sensitivity range of low-cost detectors. There was no significant fall in the diagnostic power when the spectral resolution was reduced from 3.8nm to 50nm, and when the spectral range was reduced from 320-1100nm to 400-1000nm. Therefore, in the design of the spectral imaging system emphasis was placed on spatial resolution and a standard detector was used. The spectral imaging system contains a broadband light source, diffraction grating monochromator and CMOS camera and achieves 10nm spectral resolution over a spectral range of 400-1000nm, with a spatial resolution of 40 microns over a field of view of 2cm.

About this research paper

What this paper is about

There is currently a search for an automated, objective and non-invasive system that would accurately diagnose pigmented skin tumours. Systems that measure either the spatial or the spectral characteristics of light reflected from the skin have shown promise for this purpose but only a few studies have combined spatial and spectral information. We plan to study this and consequently need to construct a cost-effective research spectral imaging system but the design will require a compromise between spatial and spectral information. Here, the effect, on diagnostic accuracy, of reducing the spectral resolution of spectrophotometry data was studied. Also studied was the effect of reducing the spectral range to that of the sensitivity range of low-cost detectors. There was no significant fall in the diagnostic power when the spectral resolution was reduced from 3.8nm to 50nm, and when the spectral range was reduced from 320-1100nm to 400-1000nm. Therefore, in the design of the spectral imaging system emphasis was placed on spatial resolution and a standard detector was used. The spectral imaging system contains a broadband light source, diffraction grating monochromator and CMOS camera and achieves 10nm spectral resolution over a spectral range of 400-1000nm, with a spatial resolution of 40 microns over a field of view of 2cm.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

There is currently a search for an automated, objective and non-invasive system that would accurately diagnose pigmented skin tumours. Systems that measure either the spatial or the spectral characteristics of light reflected from the skin have shown promise for this purpose but only a few studies have combined spatial and spectral information. We plan to study this and consequently need to construct a cost-effective research spectral imaging system but the design will require a compromise between spatial and spectral information. Here, the effect, on diagnostic accuracy, of reducing the spectral resolution of spectrophotometry data was studied. Also studied was the effect of reducing the spectral range to that of the sensitivity range of low-cost detectors. There was no significant fall in the diagnostic power when the spectral resolution was reduced from 3.8nm to 50nm, and when the spectral range was reduced from 320-1100nm to 400-1000nm. Therefore, in the design of the spectral imaging system emphasis was placed on spatial resolution and a standard detector was used. The spectral imaging system contains a broadband light source, diffraction grating monochromator and CMOS camera and achieves 10nm spectral resolution over a spectral range of 400-1000nm, with a spatial resolution of 40 microns over a field of view of 2cm.

Key concepts: Spectral resolution, Spectral imaging, Image resolution, Full spectral imaging, Spectral sensitivity, Detector, Multispectral image, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and design of a new spectral imaging system for melanoma research — Research Paper | ScholarLens