1999Human MutationOpen access

A highly sensitive, fast, and economical technique for mutation analysis in hereditary breast and ovarian cancers

Norbert Arnold, Eva Groß, Ulrike Schwarz‐Boeger, Jacobus Pfisterer, W. Jonat, Marion B. Kiechle

Open full text 112 citations

Abstract

Mutation analysis of complex genes without hotspots for sequence variations, such as BRCA1, is time-consuming and expensive. Of all currently available methods, direct sequencing has the highest sensitivity, but also the highest costs. Other techniques, such as SSCP, DGGE, and PTT, are more economical but, depending on the experience of the investigator, have at best a sensitivity of 90%. We investigated in a prospective study the feasibility and accuracy of the DHPLC technique. We present the application of the DHPLC protocol for BRCA1 mutation detection on a HPLC device from Bio-Tek Kontron Instruments (Neufahrn, Germany). DNA from 46 women with hereditary breast and ovarian cancer undergoing genetic testing for BRCA1 mutations were tested. Of 1,518 amplicons analyzed by DHPLC, corresponding to 33 fragments spanning the entire BRCA1 gene, 626 were also directly sequenced. The comparison demonstrated that DHPLC detected all alterations found by direct sequencing. No false-positive signals were seen in cases of homozygous sequences. Further, no false-negative results were ever obtained in women with mutations or polymorphisms, or both. In cases of known genetic variations, the nature of the alterations could be predicted by DHPLC. We also compared different separation matrices. Up to about 500 injections, no significant differences in sensitivity could be observed between poly(styrene divinylbenzene) and end-capped silica based columns. However, after more than 500 injections, the resolution of hetero- from homoduplex deteriorated rapidly on silica columns.

Open-access reader

About this research paper

What this paper is about

Mutation analysis of complex genes without hotspots for sequence variations, such as BRCA1, is time-consuming and expensive. Of all currently available methods, direct sequencing has the highest sensitivity, but also the highest costs. Other techniques, such as SSCP, DGGE, and PTT, are more economical but, depending on the experience of the investigator, have at best a sensitivity of 90%. We investigated in a prospective study the feasibility and accuracy of the DHPLC technique. We present the application of the DHPLC protocol for BRCA1 mutation detection on a HPLC device from Bio-Tek Kontron Instruments (Neufahrn, Germany). DNA from 46 women with hereditary breast and ovarian cancer undergoing genetic testing for BRCA1 mutations were tested. Of 1,518 amplicons analyzed by DHPLC, corresponding to 33 fragments spanning the entire BRCA1 gene, 626 were also directly sequenced. The comparison demonstrated that DHPLC detected all alterations found by direct sequencing. No false-positive signals were seen in cases of homozygous sequences. Further, no false-negative results were ever obtained in women with mutations or polymorphisms, or both. In cases of known genetic variations, the nature of the alterations could be predicted by DHPLC. We also compared different separation matrices. Up to about 500 injections, no significant differences in sensitivity could be observed between poly(styrene divinylbenzene) and end-capped silica based columns. However, after more than 500 injections, the resolution of hetero- from homoduplex deteriorated rapidly on silica columns.

Why it matters

OpenAlex reports 112 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Mutation analysis of complex genes without hotspots for sequence variations, such as BRCA1, is time-consuming and expensive. Of all currently available methods, direct sequencing has the highest sensitivity, but also the highest costs. Other techniques, such as SSCP, DGGE, and PTT, are more economical but, depending on the experience of the investigator, have at best a sensitivity of 90%. We investigated in a prospective study the feasibility and accuracy of the DHPLC technique. We present the application of the DHPLC protocol for BRCA1 mutation detection on a HPLC device from Bio-Tek Kontron Instruments (Neufahrn, Germany). DNA from 46 women with hereditary breast and ovarian cancer undergoing genetic testing for BRCA1 mutations were tested. Of 1,518 amplicons analyzed by DHPLC, corresponding to 33 fragments spanning the entire BRCA1 gene, 626 were also directly sequenced. The comparison demonstrated that DHPLC detected all alterations found by direct sequencing. No false-positive signals were seen in cases of homozygous sequences. Further, no false-negative results were ever obtained in women with mutations or polymorphisms, or both. In cases of known genetic variations, the nature of the alterations could be predicted by DHPLC. We also compared different separation matrices. Up to about 500 injections, no significant differences in sensitivity could be observed between poly(styrene divinylbenzene) and end-capped silica based columns. However, after more than 500 injections, the resolution of hetero- from homoduplex deteriorated rapidly on silica columns.

Key concepts: Biology, Amplicon, Breast cancer, Ovarian cancer, Mutation, Single-strand conformation polymorphism, Denaturing high performance liquid chromatography, Genetics

Related papers

Back to paper searchBrowse research topicsOriginal source
A highly sensitive, fast, and economical technique for mutation analysis in hereditary breast and ovarian cancers — Research Paper | ScholarLens