2009Medical PhysicsRequires access

SU‐FF‐T‐398: Monte Carlo Simulations to Configure a Treatment Planning System for Modulated Scanning Proton Delivery

D Dolney, John E. McDonough

Open publisher page 0 citations

Abstract

Purpose: To generate a library of data in order to configure our treatment planning system for modulated, scanned proton delivery. Method and Materials: We use Monte Carlo simulations to generate modulated scanning data for our treatment planning system. A simplified model of the treatment delivery nozzle was implemented as our simulation geometry. Primary protons were generated in the nozzle just downbeam of the last pair of focusing quadrupole magnets. The phase space for these primary protons is taken to be double‐Gaussian in both spatial and angular distribution. Given the specifications of spot‐size at isocenter, the beam emittance, and that the beam be focused at isocenter, the phase space for primaries was derived by back‐transporting the spot‐size at isocenter using Fermi‐Eyges theory. Results: We find good agreement between Fermi‐Eyges theory and Monte Carlo for pencil beams propagating through vacuum and air. The difference in spot size between Fermi‐Eyges and Monte Carlo at isocenter is less than 100 um. We generate profiles and depth‐dose curves that were used to configure our treatment planning system. Conclusions: Fermi‐Eyges theory can be used to find initial phase spaces for pencils beams focused at isocenter. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17‐W81XWH‐04‐2‐0022. Opinions, interpretations, conclusions and recommendations are those of the author and are not necessarily endorsed by the US Army.

About this research paper

What this paper is about

Purpose: To generate a library of data in order to configure our treatment planning system for modulated, scanned proton delivery. Method and Materials: We use Monte Carlo simulations to generate modulated scanning data for our treatment planning system. A simplified model of the treatment delivery nozzle was implemented as our simulation geometry. Primary protons were generated in the nozzle just downbeam of the last pair of focusing quadrupole magnets. The phase space for these primary protons is taken to be double‐Gaussian in both spatial and angular distribution. Given the specifications of spot‐size at isocenter, the beam emittance, and that the beam be focused at isocenter, the phase space for primaries was derived by back‐transporting the spot‐size at isocenter using Fermi‐Eyges theory. Results: We find good agreement between Fermi‐Eyges theory and Monte Carlo for pencil beams propagating through vacuum and air. The difference in spot size between Fermi‐Eyges and Monte Carlo at isocenter is less than 100 um. We generate profiles and depth‐dose curves that were used to configure our treatment planning system. Conclusions: Fermi‐Eyges theory can be used to find initial phase spaces for pencils beams focused at isocenter. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17‐W81XWH‐04‐2‐0022. Opinions, interpretations, conclusions and recommendations are those of the author and are not necessarily endorsed by the US Army.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose: To generate a library of data in order to configure our treatment planning system for modulated, scanned proton delivery. Method and Materials: We use Monte Carlo simulations to generate modulated scanning data for our treatment planning system. A simplified model of the treatment delivery nozzle was implemented as our simulation geometry. Primary protons were generated in the nozzle just downbeam of the last pair of focusing quadrupole magnets. The phase space for these primary protons is taken to be double‐Gaussian in both spatial and angular distribution. Given the specifications of spot‐size at isocenter, the beam emittance, and that the beam be focused at isocenter, the phase space for primaries was derived by back‐transporting the spot‐size at isocenter using Fermi‐Eyges theory. Results: We find good agreement between Fermi‐Eyges theory and Monte Carlo for pencil beams propagating through vacuum and air. The difference in spot size between Fermi‐Eyges and Monte Carlo at isocenter is less than 100 um. We generate profiles and depth‐dose curves that were used to configure our treatment planning system. Conclusions: Fermi‐Eyges theory can be used to find initial phase spaces for pencils beams focused at isocenter. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17‐W81XWH‐04‐2‐0022. Opinions, interpretations, conclusions and recommendations are those of the author and are not necessarily endorsed by the US Army.

Key concepts: Isocenter, Proton therapy, Monte Carlo method, Fermi Gamma-ray Space Telescope, Phase space, Physics, Proton, Pencil-beam scanning

Related papers

Back to paper searchBrowse research topicsOriginal source
SU‐FF‐T‐398: Monte Carlo Simulations to Configure a Treatment Planning System for Modulated Scanning Proton Delivery — Research Paper | ScholarLens