2004Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

Fiber optic infrared multispectral radiometers for emissivity and temperature measurements of gray bodies near room temperatures

Sharon Sade, Igor Uman, Veena Gopal, James A. Harrington, Abraham Katzir

Open publisher page 1 citations

Abstract

Two fiberoptic infrared multi-spectral radiometers were constructed for measurements of the temperature and the emissivity of gray bodies whose temperatures were close to room temperature (40-70°C). In one radiometer, the different spectral regions were obtained by using standard bulk interference filters, and in a second radiometer, the different spectral regions were obtained by using hollow glass waveguides (HGWs) as filters. Using these two radiometers, we carried out temperature and emissivity measurements of three gray bodies which had high emissivity (ε=0.97), medium emissivity (ε=0.71) and low emissivity (ε=0.025). We present the results obtained for these gray bodies and discuss the advantages and disadvantages using each of the radiometers.

About this research paper

What this paper is about

Two fiberoptic infrared multi-spectral radiometers were constructed for measurements of the temperature and the emissivity of gray bodies whose temperatures were close to room temperature (40-70°C). In one radiometer, the different spectral regions were obtained by using standard bulk interference filters, and in a second radiometer, the different spectral regions were obtained by using hollow glass waveguides (HGWs) as filters. Using these two radiometers, we carried out temperature and emissivity measurements of three gray bodies which had high emissivity (ε=0.97), medium emissivity (ε=0.71) and low emissivity (ε=0.025). We present the results obtained for these gray bodies and discuss the advantages and disadvantages using each of the radiometers.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Two fiberoptic infrared multi-spectral radiometers were constructed for measurements of the temperature and the emissivity of gray bodies whose temperatures were close to room temperature (40-70°C). In one radiometer, the different spectral regions were obtained by using standard bulk interference filters, and in a second radiometer, the different spectral regions were obtained by using hollow glass waveguides (HGWs) as filters. Using these two radiometers, we carried out temperature and emissivity measurements of three gray bodies which had high emissivity (ε=0.97), medium emissivity (ε=0.71) and low emissivity (ε=0.025). We present the results obtained for these gray bodies and discuss the advantages and disadvantages using each of the radiometers.

Key concepts: Emissivity, Multispectral image, Radiometer, Materials science, Infrared, Radiometry, Temperature measurement, Remote sensing