2011•Journal of Separation ScienceRequires access

Simple preparative gas chromatographic method for isolation of menthol and menthone from peppermint oil, with quantitative GC‐MS and 1H NMR assay

Hae Eun Park, Seung‐Ok Yang, Sun Hee Hyun, Shin Jung Park, Hyung‐Kyoon Choi, Philip John Marriott

Open publisher page 24 citations

Abstract

The quantitative performance of a simple home-built preparative gas chromatography (prep-GC) arrangement was tested, incorporating a micro-fluidic Deans switch, with collection of the target compound in a deactivated uncoated capillary tube. Repeat injections of a standard solution and peppermint sample were made into the prep-GC instrument. Individual compounds were eluted from the trapping capillary, and made up to constant volume. Chloronaphthalene internal standard was added in some cases. Recovered samples were quantitatively assayed by using GC-MS. Calibration linearity of GC-MS for menthol standard area response against number of injections (2-20 repeat injections) was excellent, giving R(2) of 0.996. For peppermint, menthol correlation over 2-20 repeated injections was 0.998 for menthol area ratio (versus IS) data. Menthone calibration for peppermint gave an R(2) of 0.972. (1) H NMR spectroscopy was conducted on both menthol and menthone. Good correspondence with reference spectra was obtained. About 80 μg of isolated menthol and menthone solute was collected over a sequence of 80 repeat injections from the peppermint sample, as assayed by 600 MHz (1) H NMR analysis (∼100% recovery for menthol from peppermint). A procedure is proposed for prediction of number of injections required to acquire sufficient material for NMR detection.

About this research paper

What this paper is about

The quantitative performance of a simple home-built preparative gas chromatography (prep-GC) arrangement was tested, incorporating a micro-fluidic Deans switch, with collection of the target compound in a deactivated uncoated capillary tube. Repeat injections of a standard solution and peppermint sample were made into the prep-GC instrument. Individual compounds were eluted from the trapping capillary, and made up to constant volume. Chloronaphthalene internal standard was added in some cases. Recovered samples were quantitatively assayed by using GC-MS. Calibration linearity of GC-MS for menthol standard area response against number of injections (2-20 repeat injections) was excellent, giving R(2) of 0.996. For peppermint, menthol correlation over 2-20 repeated injections was 0.998 for menthol area ratio (versus IS) data. Menthone calibration for peppermint gave an R(2) of 0.972. (1) H NMR spectroscopy was conducted on both menthol and menthone. Good correspondence with reference spectra was obtained. About 80 μg of isolated menthol and menthone solute was collected over a sequence of 80 repeat injections from the peppermint sample, as assayed by 600 MHz (1) H NMR analysis (∼100% recovery for menthol from peppermint). A procedure is proposed for prediction of number of injections required to acquire sufficient material for NMR detection.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The quantitative performance of a simple home-built preparative gas chromatography (prep-GC) arrangement was tested, incorporating a micro-fluidic Deans switch, with collection of the target compound in a deactivated uncoated capillary tube. Repeat injections of a standard solution and peppermint sample were made into the prep-GC instrument. Individual compounds were eluted from the trapping capillary, and made up to constant volume. Chloronaphthalene internal standard was added in some cases. Recovered samples were quantitatively assayed by using GC-MS. Calibration linearity of GC-MS for menthol standard area response against number of injections (2-20 repeat injections) was excellent, giving R(2) of 0.996. For peppermint, menthol correlation over 2-20 repeated injections was 0.998 for menthol area ratio (versus IS) data. Menthone calibration for peppermint gave an R(2) of 0.972. (1) H NMR spectroscopy was conducted on both menthol and menthone. Good correspondence with reference spectra was obtained. About 80 μg of isolated menthol and menthone solute was collected over a sequence of 80 repeat injections from the peppermint sample, as assayed by 600 MHz (1) H NMR analysis (∼100% recovery for menthol from peppermint). A procedure is proposed for prediction of number of injections required to acquire sufficient material for NMR detection.

Key concepts: Menthone, Menthol, Chromatography, Chemistry, Gas chromatography, Analytical Chemistry (journal), Essential oil, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simple preparative gas chromatographic method for isolation of menthol and menthone from peppermint oil, with quantitative GC‐MS and 1H NMR assay — Research Paper | ScholarLens