Development of an LDMA-FCE System for the Measurement of Submicron Aerosol Particles

Manabu Shimada, Hye Moon Lee, Chan Soo Kim, Hiromi Koyama, Toshihiko Myojo, Kikuo Okuyama

Open publisher page 13 citations

Abstract

An LDMA-FCE (long differential mobility analyzer–faraday cup electrometer) system capable of measuring particle sizes up to larger than 1 μm was developed, and a data reduction process for converting an electrical mobility distribution measured by the LDMA-FCE system into a particle size distribution was derived by the modification of a process previously used for a DMA-CNC (differential mobility analyzer–condensation nucleus counter) system. The performance of the LDMA was evaluated by a tandem DMA system, electrical classification of the PSL standard particles, and field emission-scanning electron microscopy observations. The accuracy of the modified data reduction process was confirmed by comparing particle size distributions measured by the LDMA-FCE system with those determined using an LDMA-CNC system. Particle electrical mobility distributions, as measured by the tandem DMA system, were in good agreement with the theoretical distribution. Good agreement was also found between particle size distributions measured with the LDMA-FCE and the LDMA-CNC systems. Thus, the LDMA-FCE system performed well and represents a useful device for measuring the size of submicron aerosol particles over a wide range.

About this research paper

What this paper is about

An LDMA-FCE (long differential mobility analyzer–faraday cup electrometer) system capable of measuring particle sizes up to larger than 1 μm was developed, and a data reduction process for converting an electrical mobility distribution measured by the LDMA-FCE system into a particle size distribution was derived by the modification of a process previously used for a DMA-CNC (differential mobility analyzer–condensation nucleus counter) system. The performance of the LDMA was evaluated by a tandem DMA system, electrical classification of the PSL standard particles, and field emission-scanning electron microscopy observations. The accuracy of the modified data reduction process was confirmed by comparing particle size distributions measured by the LDMA-FCE system with those determined using an LDMA-CNC system. Particle electrical mobility distributions, as measured by the tandem DMA system, were in good agreement with the theoretical distribution. Good agreement was also found between particle size distributions measured with the LDMA-FCE and the LDMA-CNC systems. Thus, the LDMA-FCE system performed well and represents a useful device for measuring the size of submicron aerosol particles over a wide range.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An LDMA-FCE (long differential mobility analyzer–faraday cup electrometer) system capable of measuring particle sizes up to larger than 1 μm was developed, and a data reduction process for converting an electrical mobility distribution measured by the LDMA-FCE system into a particle size distribution was derived by the modification of a process previously used for a DMA-CNC (differential mobility analyzer–condensation nucleus counter) system. The performance of the LDMA was evaluated by a tandem DMA system, electrical classification of the PSL standard particles, and field emission-scanning electron microscopy observations. The accuracy of the modified data reduction process was confirmed by comparing particle size distributions measured by the LDMA-FCE system with those determined using an LDMA-CNC system. Particle electrical mobility distributions, as measured by the tandem DMA system, were in good agreement with the theoretical distribution. Good agreement was also found between particle size distributions measured with the LDMA-FCE and the LDMA-CNC systems. Thus, the LDMA-FCE system performed well and represents a useful device for measuring the size of submicron aerosol particles over a wide range.

Key concepts: Differential mobility analyzer, Faraday cup, Electrometer, Electrical mobility, Condensation particle counter, Spectrum analyzer, Aerosol, Particle (ecology)