2009British Journal of OphthalmologyOpen access

Use of hydroxypropylmethylcellulose 2% for removing adherent silicone oil from silicone intraocular lenses

Sui Chien Wong, Yashin Ramkissoon, M Lopez, Kristopher Page, Ivan P. Parkin, Paul Sullivan

Open full text 12 citations

Abstract

BACKGROUND/AIMS: To investigate the effect of hydroxypropylmethylcellulose (HPMC) on the physical interaction (contact angle) between silicone oil and a silicone intraocular lens (IOL). METHODS: In vitro experiments were performed, to determine the effect of HPMC (0.5%, 1% or 2%), with or without an additional simple mechanical manoeuvre, on the contact angle of silicone oil at the surface of both silicone and acrylic (control) IOLs. A balanced salt solution chamber was used. The study group comprised 21 silicone and nine acrylic IOLs. RESULTS: The median contact angle of silicone oil on silicone IOL was 99 degrees. The addition of HPMC 2% alone did not significantly alter the contact angle. HPMC 2% combined with an additional single mechanical manoeuvre increased the contact angle to 180 degrees (greater non-wetting), with complete separation of silicone oil from silicone IOL within 1 min. The manoeuvre alone, or in conjunction with a lower concentration of HPMC (0.5 or 1%), was ineffective in increasing the contact angle. CONCLUSION: We present a novel, non-toxic technique of using hydroxypropylmethylcellulose 2% combined with a simple mechanical manoeuvre, for the removal of adherent silicone oil droplets from silicone intraocular lenses.

About this research paper

What this paper is about

BACKGROUND/AIMS: To investigate the effect of hydroxypropylmethylcellulose (HPMC) on the physical interaction (contact angle) between silicone oil and a silicone intraocular lens (IOL). METHODS: In vitro experiments were performed, to determine the effect of HPMC (0.5%, 1% or 2%), with or without an additional simple mechanical manoeuvre, on the contact angle of silicone oil at the surface of both silicone and acrylic (control) IOLs. A balanced salt solution chamber was used. The study group comprised 21 silicone and nine acrylic IOLs. RESULTS: The median contact angle of silicone oil on silicone IOL was 99 degrees. The addition of HPMC 2% alone did not significantly alter the contact angle. HPMC 2% combined with an additional single mechanical manoeuvre increased the contact angle to 180 degrees (greater non-wetting), with complete separation of silicone oil from silicone IOL within 1 min. The manoeuvre alone, or in conjunction with a lower concentration of HPMC (0.5 or 1%), was ineffective in increasing the contact angle. CONCLUSION: We present a novel, non-toxic technique of using hydroxypropylmethylcellulose 2% combined with a simple mechanical manoeuvre, for the removal of adherent silicone oil droplets from silicone intraocular lenses.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND/AIMS: To investigate the effect of hydroxypropylmethylcellulose (HPMC) on the physical interaction (contact angle) between silicone oil and a silicone intraocular lens (IOL). METHODS: In vitro experiments were performed, to determine the effect of HPMC (0.5%, 1% or 2%), with or without an additional simple mechanical manoeuvre, on the contact angle of silicone oil at the surface of both silicone and acrylic (control) IOLs. A balanced salt solution chamber was used. The study group comprised 21 silicone and nine acrylic IOLs. RESULTS: The median contact angle of silicone oil on silicone IOL was 99 degrees. The addition of HPMC 2% alone did not significantly alter the contact angle. HPMC 2% combined with an additional single mechanical manoeuvre increased the contact angle to 180 degrees (greater non-wetting), with complete separation of silicone oil from silicone IOL within 1 min. The manoeuvre alone, or in conjunction with a lower concentration of HPMC (0.5 or 1%), was ineffective in increasing the contact angle. CONCLUSION: We present a novel, non-toxic technique of using hydroxypropylmethylcellulose 2% combined with a simple mechanical manoeuvre, for the removal of adherent silicone oil droplets from silicone intraocular lenses.

Key concepts: Silicone oil, Silicone, Contact angle, Wetting, Intraocular lenses, Intraocular lens, Ophthalmology, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of hydroxypropylmethylcellulose 2% for removing adherent silicone oil from silicone intraocular lenses — Research Paper | ScholarLens