1995•Magnetic Resonance in MedicineRequires access

NMR Microscopy of Single Neurons Using Spin Echo and Line Narrowed 2DFT Imaging

Richard W Bowtell, Andrew M. Peters, Jonathan C. Sharp, Peter R. Mansfield, Edward W. Hsu, Nanci R. Aiken, Anthony Horsman, Stephen John Blackband

Open publisher page 40 citations

Abstract

NMR microimages of single neural cells were acquired at 500 MHz using a conventional spin echo pulse sequence and a line-narrowing sequence that eliminates susceptibility effects. The data show that any contribution to the measured T2 relaxation rate arising from diffusion in local field inhomogeneities using spin echo sequences at high fields and high spatial resolution is relatively small. We conclude that the measured T2 difference between the nucleus and cytoplasm in these cells represents primarily a true T2 relaxation effect arising from the interactions of water with macromolecules in the two compartments and does not result from microsusceptibility differences. These observations have implications regarding water compartmentation in single cells and the interpretation of the MR characteristics of tissues in vivo.

About this research paper

What this paper is about

NMR microimages of single neural cells were acquired at 500 MHz using a conventional spin echo pulse sequence and a line-narrowing sequence that eliminates susceptibility effects. The data show that any contribution to the measured T2 relaxation rate arising from diffusion in local field inhomogeneities using spin echo sequences at high fields and high spatial resolution is relatively small. We conclude that the measured T2 difference between the nucleus and cytoplasm in these cells represents primarily a true T2 relaxation effect arising from the interactions of water with macromolecules in the two compartments and does not result from microsusceptibility differences. These observations have implications regarding water compartmentation in single cells and the interpretation of the MR characteristics of tissues in vivo.

Why it matters

OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

NMR microimages of single neural cells were acquired at 500 MHz using a conventional spin echo pulse sequence and a line-narrowing sequence that eliminates susceptibility effects. The data show that any contribution to the measured T2 relaxation rate arising from diffusion in local field inhomogeneities using spin echo sequences at high fields and high spatial resolution is relatively small. We conclude that the measured T2 difference between the nucleus and cytoplasm in these cells represents primarily a true T2 relaxation effect arising from the interactions of water with macromolecules in the two compartments and does not result from microsusceptibility differences. These observations have implications regarding water compartmentation in single cells and the interpretation of the MR characteristics of tissues in vivo.

Key concepts: Nuclear magnetic resonance, Spin echo, Pulse sequence, Relaxation (psychology), Echo (communications protocol), Nucleus, Line (geometry), Pulse (music)

Related papers

Back to paper searchBrowse research topicsOriginal source
NMR Microscopy of Single Neurons Using Spin Echo and Line Narrowed 2DFT Imaging — Research Paper | ScholarLens