2005European Journal of AnaesthesiologyRequires access

Modelling the pharmacodynamic interaction between remifentanil and propofol by EEG-controlled dosing

J. Fechner, W. Hering, Harald Ihmsen, Thomas Palmaers, J. Schüttler, Susanne Albrecht

Open publisher page 17 citations

Abstract

BACKGROUND AND OBJECTIVE: Knowledge of the pharmacodynamic interaction between remifentanil and propofol is important to permit optimal dosage strategies. We studied this pharmacodynamic interaction using the median power frequency of the processed electroencephalogram as a control parameter for feedback-controlled dosing of propofol. METHODS: Twenty-one patients were given total intravenous anaesthesia with remifentanil and propofol. During three target-controlled infusion regimens, the target concentrations of remifentanil (5, 10, 15 ng mL(-1)) and propofol dosing were automatically adjusted to keep the median power frequency in the range 2 +/- 0.5 Hz. In each patient and during each remifentanil target concentration, four arterial propofol/remifentanil concentration pairs were measured. The type of interaction was tested using the relative distance from the line of additivity and the isobole was modelled using Bernstein splines. RESULTS: The results from 13 patients were used for data analysis. The measured remifentanil concentrations during the three targets were (mean +/- SD): 3.6 +/- 0.9, 8.1 +/- 2.5 and 12.4 +/- 2.8 ng mL(-1). The corresponding propofol concentrations were 2.64 +/- 0.86, 2.13 +/- 0.58 and 2.09 +/- 0.58 microg mL(-1). The data were best described with an additive type of interaction and the isobole was estimated using: ((c)Remifentanil/64.2 ng mL(-1)) + ((c)Propofol/2.61 microg mL(-1)) = 1. CONCLUSIONS: Within the studied concentration range, remifentanil and propofol showed an additive type of pharmacodynamic interaction on the electroencephalogram.

About this research paper

What this paper is about

BACKGROUND AND OBJECTIVE: Knowledge of the pharmacodynamic interaction between remifentanil and propofol is important to permit optimal dosage strategies. We studied this pharmacodynamic interaction using the median power frequency of the processed electroencephalogram as a control parameter for feedback-controlled dosing of propofol. METHODS: Twenty-one patients were given total intravenous anaesthesia with remifentanil and propofol. During three target-controlled infusion regimens, the target concentrations of remifentanil (5, 10, 15 ng mL(-1)) and propofol dosing were automatically adjusted to keep the median power frequency in the range 2 +/- 0.5 Hz. In each patient and during each remifentanil target concentration, four arterial propofol/remifentanil concentration pairs were measured. The type of interaction was tested using the relative distance from the line of additivity and the isobole was modelled using Bernstein splines. RESULTS: The results from 13 patients were used for data analysis. The measured remifentanil concentrations during the three targets were (mean +/- SD): 3.6 +/- 0.9, 8.1 +/- 2.5 and 12.4 +/- 2.8 ng mL(-1). The corresponding propofol concentrations were 2.64 +/- 0.86, 2.13 +/- 0.58 and 2.09 +/- 0.58 microg mL(-1). The data were best described with an additive type of interaction and the isobole was estimated using: ((c)Remifentanil/64.2 ng mL(-1)) + ((c)Propofol/2.61 microg mL(-1)) = 1. CONCLUSIONS: Within the studied concentration range, remifentanil and propofol showed an additive type of pharmacodynamic interaction on the electroencephalogram.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND AND OBJECTIVE: Knowledge of the pharmacodynamic interaction between remifentanil and propofol is important to permit optimal dosage strategies. We studied this pharmacodynamic interaction using the median power frequency of the processed electroencephalogram as a control parameter for feedback-controlled dosing of propofol. METHODS: Twenty-one patients were given total intravenous anaesthesia with remifentanil and propofol. During three target-controlled infusion regimens, the target concentrations of remifentanil (5, 10, 15 ng mL(-1)) and propofol dosing were automatically adjusted to keep the median power frequency in the range 2 +/- 0.5 Hz. In each patient and during each remifentanil target concentration, four arterial propofol/remifentanil concentration pairs were measured. The type of interaction was tested using the relative distance from the line of additivity and the isobole was modelled using Bernstein splines. RESULTS: The results from 13 patients were used for data analysis. The measured remifentanil concentrations during the three targets were (mean +/- SD): 3.6 +/- 0.9, 8.1 +/- 2.5 and 12.4 +/- 2.8 ng mL(-1). The corresponding propofol concentrations were 2.64 +/- 0.86, 2.13 +/- 0.58 and 2.09 +/- 0.58 microg mL(-1). The data were best described with an additive type of interaction and the isobole was estimated using: ((c)Remifentanil/64.2 ng mL(-1)) + ((c)Propofol/2.61 microg mL(-1)) = 1. CONCLUSIONS: Within the studied concentration range, remifentanil and propofol showed an additive type of pharmacodynamic interaction on the electroencephalogram.

Key concepts: Remifentanil, Propofol, Pharmacodynamics, Medicine, Anesthesia, Dosing, Target controlled infusion, Pharmacokinetics