2015•OphthalmologicaRequires access

Repeatability of Retinal Macular Thickness Measurements in Healthy Subjects and Diabetic Patients with Clinically Significant Macular Edema: Evaluation of the Follow-Up System of Spectralis Optical Coherence Tomography

Tito Fiore, Marco Lupidi, Sofia N. Androudi, Fabrizio Giansanti, Daniela Fruttini, Carlo Cagini

Open publisher page 10 citations

Abstract

BACKGROUND: It was the aim of this study to compare the repeatability of Spectralis optical coherence tomography (OCT) retinal thickness measurements in healthy subjects and diabetic patients with clinically significant macular edema (CSME) with or without the use of the follow-up system. METHODS: Thirty-eight eyes of 38 healthy subjects (control group) and 68 eyes of 68 diabetic patients with CSME were included in the study. The coefficient of repeatability (CR) and intrasession coefficients of variation were tested with 20 × 15 degree raster scans consisting of 19 high-resolution line scans (15 frames per scan) that were repeated 3 times by 1 experienced examiner. The first scan was set as the reference scan, whereas the second and third scans were the follow-up scans and were performed with and without the use of the follow-up mode, respectively. RESULTS: The means and standard deviations for the central foveal subfield (CSF) in healthy subjects and diabetic patients were 289 ± 21 and 402 ± 105 μm, respectively. Particularly in diabetic patients, examining the CSF, CR was 2.67% (10.73 µm) and 6.73% (27.01 µm) with and without using the follow-up mode, respectively, and the difference was statistically significant (p < 0.05). CONCLUSION: These results support the hypothesis that the follow-up system improves the repeatability either in healthy subjects or in diabetic patients with poor fixation. The wider improvement in repeatability in diabetic patients in the follow-up system group compared to the no follow-up system group are probably related to poor patient fixation or eye movement in patients with CSME.

About this research paper

What this paper is about

BACKGROUND: It was the aim of this study to compare the repeatability of Spectralis optical coherence tomography (OCT) retinal thickness measurements in healthy subjects and diabetic patients with clinically significant macular edema (CSME) with or without the use of the follow-up system. METHODS: Thirty-eight eyes of 38 healthy subjects (control group) and 68 eyes of 68 diabetic patients with CSME were included in the study. The coefficient of repeatability (CR) and intrasession coefficients of variation were tested with 20 × 15 degree raster scans consisting of 19 high-resolution line scans (15 frames per scan) that were repeated 3 times by 1 experienced examiner. The first scan was set as the reference scan, whereas the second and third scans were the follow-up scans and were performed with and without the use of the follow-up mode, respectively. RESULTS: The means and standard deviations for the central foveal subfield (CSF) in healthy subjects and diabetic patients were 289 ± 21 and 402 ± 105 μm, respectively. Particularly in diabetic patients, examining the CSF, CR was 2.67% (10.73 µm) and 6.73% (27.01 µm) with and without using the follow-up mode, respectively, and the difference was statistically significant (p < 0.05). CONCLUSION: These results support the hypothesis that the follow-up system improves the repeatability either in healthy subjects or in diabetic patients with poor fixation. The wider improvement in repeatability in diabetic patients in the follow-up system group compared to the no follow-up system group are probably related to poor patient fixation or eye movement in patients with CSME.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: It was the aim of this study to compare the repeatability of Spectralis optical coherence tomography (OCT) retinal thickness measurements in healthy subjects and diabetic patients with clinically significant macular edema (CSME) with or without the use of the follow-up system. METHODS: Thirty-eight eyes of 38 healthy subjects (control group) and 68 eyes of 68 diabetic patients with CSME were included in the study. The coefficient of repeatability (CR) and intrasession coefficients of variation were tested with 20 × 15 degree raster scans consisting of 19 high-resolution line scans (15 frames per scan) that were repeated 3 times by 1 experienced examiner. The first scan was set as the reference scan, whereas the second and third scans were the follow-up scans and were performed with and without the use of the follow-up mode, respectively. RESULTS: The means and standard deviations for the central foveal subfield (CSF) in healthy subjects and diabetic patients were 289 ± 21 and 402 ± 105 μm, respectively. Particularly in diabetic patients, examining the CSF, CR was 2.67% (10.73 µm) and 6.73% (27.01 µm) with and without using the follow-up mode, respectively, and the difference was statistically significant (p < 0.05). CONCLUSION: These results support the hypothesis that the follow-up system improves the repeatability either in healthy subjects or in diabetic patients with poor fixation. The wider improvement in repeatability in diabetic patients in the follow-up system group compared to the no follow-up system group are probably related to poor patient fixation or eye movement in patients with CSME.

Key concepts: Optical coherence tomography, Repeatability, Medicine, Ophthalmology, Diabetic macular edema, Retinal, Macular edema, Optometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Repeatability of Retinal Macular Thickness Measurements in Healthy Subjects and Diabetic Patients with Clinically Significant Macular Edema: Evaluation of the Follow-Up System of Spectralis Optical Coherence Tomography — Research Paper | ScholarLens