2001Journal of Magnetic Resonance ImagingRequires access

Fat‐suppressed T2‐weighted MRI of the liver: Comparison of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences

Motoyuki Katayama, Takayuki Masui, Shigeru Kobayashi, Tatsuhiko Ito, Mamoru Takahashi, Harumi Sakahara, Atsushi Nozaki, Hiroyuki Kabasawa

Open publisher page 42 citations

Abstract

The purpose of our study was to compare the value of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences in detecting hepatic lesions. Fat-suppressed T2-weighted magnetic resonance (MR) images obtained with the three sequences in 36 patients with 138 lesions and nine patients without lesions were prospectively analyzed. Quantitative and qualitative analyses, including receiver operating characteristic (ROC) analyses, were performed. The mean lesion-to-liver contrast-to-noise ratio (CNR) for hepatic lesions was highest with the respiratory-triggered fast spin-echo sequence. On the basis of receiver-operating characteristic analyses, tumor detection rates were higher with the breath-hold fast-recovery fast spin-echo sequence (Az = 0.94) than with the respiratory-triggered fast spin-echo sequence (AZ = 0.80, P < 0.0001) or the single-shot fast spin-echo sequence (Az = 0.77, P < 0.0001). The image quality with the breath-hold fast-recovery fast spin-echo sequence was acceptable in all patients. The breath-hold fast-recovery fast spin-echo sequence provided the highest tumor detection in a short imaging time, although the mean lesion-to-liver CNRs were inferior to those of the respiratory-triggered fast spin-echo and the breath-hold single-shot fast spin-echo sequences.

About this research paper

What this paper is about

The purpose of our study was to compare the value of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences in detecting hepatic lesions. Fat-suppressed T2-weighted magnetic resonance (MR) images obtained with the three sequences in 36 patients with 138 lesions and nine patients without lesions were prospectively analyzed. Quantitative and qualitative analyses, including receiver operating characteristic (ROC) analyses, were performed. The mean lesion-to-liver contrast-to-noise ratio (CNR) for hepatic lesions was highest with the respiratory-triggered fast spin-echo sequence. On the basis of receiver-operating characteristic analyses, tumor detection rates were higher with the breath-hold fast-recovery fast spin-echo sequence (Az = 0.94) than with the respiratory-triggered fast spin-echo sequence (AZ = 0.80, P < 0.0001) or the single-shot fast spin-echo sequence (Az = 0.77, P < 0.0001). The image quality with the breath-hold fast-recovery fast spin-echo sequence was acceptable in all patients. The breath-hold fast-recovery fast spin-echo sequence provided the highest tumor detection in a short imaging time, although the mean lesion-to-liver CNRs were inferior to those of the respiratory-triggered fast spin-echo and the breath-hold single-shot fast spin-echo sequences.

Why it matters

OpenAlex reports 42 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of our study was to compare the value of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences in detecting hepatic lesions. Fat-suppressed T2-weighted magnetic resonance (MR) images obtained with the three sequences in 36 patients with 138 lesions and nine patients without lesions were prospectively analyzed. Quantitative and qualitative analyses, including receiver operating characteristic (ROC) analyses, were performed. The mean lesion-to-liver contrast-to-noise ratio (CNR) for hepatic lesions was highest with the respiratory-triggered fast spin-echo sequence. On the basis of receiver-operating characteristic analyses, tumor detection rates were higher with the breath-hold fast-recovery fast spin-echo sequence (Az = 0.94) than with the respiratory-triggered fast spin-echo sequence (AZ = 0.80, P < 0.0001) or the single-shot fast spin-echo sequence (Az = 0.77, P < 0.0001). The image quality with the breath-hold fast-recovery fast spin-echo sequence was acceptable in all patients. The breath-hold fast-recovery fast spin-echo sequence provided the highest tumor detection in a short imaging time, although the mean lesion-to-liver CNRs were inferior to those of the respiratory-triggered fast spin-echo and the breath-hold single-shot fast spin-echo sequences.

Key concepts: Fast spin echo, Spin echo, Echo (communications protocol), Magnetic resonance imaging, Respiratory system, Nuclear magnetic resonance, Medicine, Single shot

Related papers

Back to paper searchBrowse research topicsOriginal source
Fat‐suppressed T2‐weighted MRI of the liver: Comparison of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences — Research Paper | ScholarLens