1975Review of Scientific InstrumentsRequires access

Multidimensional gamma−ray spectrometer with a liquid−scintillation−counter anticoincidence ring

R. Grismore, A. W. Barbee, Melissa Berry, Anibal L. Taboas, D. R. Emmons

Open publisher page 2 citations

Abstract

Details are given of a NaI(Tl) multidimensional gamma−ray spectrometer employing a low−cost liquid−scintillation−counter anticoincidence ring which has been constructed at Indiana State University. Data are presented on the background counting rates of this spectrometer both with and without the anticoincidence ring operating, and comparisons are made with the background of a very similar spectrometer employing a NaI(Tl) anticoincidence ring. The liquid−scintillator anticoincidence ring is shown to be effective, and capable of improvement so as to bring the background of the spectrometer down to nearly the same level as with a NaI(Tl) ring.

About this research paper

What this paper is about

Details are given of a NaI(Tl) multidimensional gamma−ray spectrometer employing a low−cost liquid−scintillation−counter anticoincidence ring which has been constructed at Indiana State University. Data are presented on the background counting rates of this spectrometer both with and without the anticoincidence ring operating, and comparisons are made with the background of a very similar spectrometer employing a NaI(Tl) anticoincidence ring. The liquid−scintillator anticoincidence ring is shown to be effective, and capable of improvement so as to bring the background of the spectrometer down to nearly the same level as with a NaI(Tl) ring.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Details are given of a NaI(Tl) multidimensional gamma−ray spectrometer employing a low−cost liquid−scintillation−counter anticoincidence ring which has been constructed at Indiana State University. Data are presented on the background counting rates of this spectrometer both with and without the anticoincidence ring operating, and comparisons are made with the background of a very similar spectrometer employing a NaI(Tl) anticoincidence ring. The liquid−scintillator anticoincidence ring is shown to be effective, and capable of improvement so as to bring the background of the spectrometer down to nearly the same level as with a NaI(Tl) ring.

Key concepts: Spectrometer, Scintillator, Physics, Liquid scintillation counting, Scintillation counter, Gamma ray spectrometer, Ring (chemistry), Scintillation

Related papers

Back to paper searchBrowse research topicsOriginal source
Multidimensional gamma−ray spectrometer with a liquid−scintillation−counter anticoincidence ring — Research Paper | ScholarLens