A New Slit Lamp–Based Technique for Anterior Chamber Angle Estimation

Joan Gispets, Genı́s Cardona, Núria Tomás, Cèlia Fusté, Alison M. Binns, Miguel A. Fortes

Open full text 2 citations

Abstract

PURPOSE: To design and test a new noninvasive method for anterior chamber angle (ACA) estimation based on the slit lamp that is accessible to all eye-care professionals. METHODS: A new technique (slit lamp anterior chamber estimation [SLACE]) that aims to overcome some of the limitations of the van Herick procedure was designed. The technique, which only requires a slit lamp, was applied to estimate the ACA of 50 participants (100 eyes) using two different slit lamp models, and results were compared with gonioscopy as the clinical standard. RESULTS: The Spearman nonparametric correlation between ACA values as determined by gonioscopy and SLACE were 0.81 (p < 0.001) and 0.79 (p < 0.001) for each slit lamp. Sensitivity values of 100 and 87.5% and specificity values of 75 and 81.2%, depending on the slit lamp used, were obtained for the SLACE technique as compared with gonioscopy (Spaeth classification). CONCLUSIONS: The SLACE technique, when compared with gonioscopy, displayed good accuracy in the detection of narrow angles, and it may be useful for eye-care clinicians without access to expensive alternative equipment or those who cannot perform gonioscopy because of legal constraints regarding the use of diagnostic drugs.

Open-access reader

About this research paper

What this paper is about

PURPOSE: To design and test a new noninvasive method for anterior chamber angle (ACA) estimation based on the slit lamp that is accessible to all eye-care professionals. METHODS: A new technique (slit lamp anterior chamber estimation [SLACE]) that aims to overcome some of the limitations of the van Herick procedure was designed. The technique, which only requires a slit lamp, was applied to estimate the ACA of 50 participants (100 eyes) using two different slit lamp models, and results were compared with gonioscopy as the clinical standard. RESULTS: The Spearman nonparametric correlation between ACA values as determined by gonioscopy and SLACE were 0.81 (p < 0.001) and 0.79 (p < 0.001) for each slit lamp. Sensitivity values of 100 and 87.5% and specificity values of 75 and 81.2%, depending on the slit lamp used, were obtained for the SLACE technique as compared with gonioscopy (Spaeth classification). CONCLUSIONS: The SLACE technique, when compared with gonioscopy, displayed good accuracy in the detection of narrow angles, and it may be useful for eye-care clinicians without access to expensive alternative equipment or those who cannot perform gonioscopy because of legal constraints regarding the use of diagnostic drugs.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To design and test a new noninvasive method for anterior chamber angle (ACA) estimation based on the slit lamp that is accessible to all eye-care professionals. METHODS: A new technique (slit lamp anterior chamber estimation [SLACE]) that aims to overcome some of the limitations of the van Herick procedure was designed. The technique, which only requires a slit lamp, was applied to estimate the ACA of 50 participants (100 eyes) using two different slit lamp models, and results were compared with gonioscopy as the clinical standard. RESULTS: The Spearman nonparametric correlation between ACA values as determined by gonioscopy and SLACE were 0.81 (p < 0.001) and 0.79 (p < 0.001) for each slit lamp. Sensitivity values of 100 and 87.5% and specificity values of 75 and 81.2%, depending on the slit lamp used, were obtained for the SLACE technique as compared with gonioscopy (Spaeth classification). CONCLUSIONS: The SLACE technique, when compared with gonioscopy, displayed good accuracy in the detection of narrow angles, and it may be useful for eye-care clinicians without access to expensive alternative equipment or those who cannot perform gonioscopy because of legal constraints regarding the use of diagnostic drugs.

Key concepts: Gonioscopy, Slit lamp, Anterior chamber angle, Ophthalmology, Glaucoma, Optometry, Optics, Slit

Related papers

Back to paper searchBrowse research topicsOriginal source
A New Slit Lamp–Based Technique for Anterior Chamber Angle Estimation — Research Paper | ScholarLens