2005•Journal of Analytical Atomic SpectrometryRequires access

Flow on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry for selective As(iii) determination in sea-water samples

Paloma Herbello-Hermelo, María Carmen Barciela‐Alonso, Adela Bermejo-Barrera, Pilar Bermejo‐Barrera

Open publisher page 27 citations

Abstract

A flow injection on-line sorption preconcentration system using a polytetrafluoroethylene (PTFE) knotted reactor was coupled with electrothermal atomic absorption spectrometry (ETAAS) to determine selectively As(III) in sea-water samples. Separation of arsenic inorganic species was achieved by the on-line formation of As(III)–pyrrolidine dithiocarbamate (PDC) complex in an acid medium, its sorption onto the inner walls of the knotted reactor (KR) and elution with 40 μl of ethanol. An enhancement factor (EF) of 44 was obtained compared with the slope of the linear portion of the calibration curve before and after preconcentration The detection limit (3 s) was 0.008 μg l−1 As(III). The precision (RSD n = 11) was 4.5% at 0.1 μg l−1 As(III). The accuracy was demonstrated by total arsenic determination in certificed reference material, NASS-4, after pre-reduction of As(V) with L-cysteine 0.25% (m/v).

About this research paper

What this paper is about

A flow injection on-line sorption preconcentration system using a polytetrafluoroethylene (PTFE) knotted reactor was coupled with electrothermal atomic absorption spectrometry (ETAAS) to determine selectively As(III) in sea-water samples. Separation of arsenic inorganic species was achieved by the on-line formation of As(III)–pyrrolidine dithiocarbamate (PDC) complex in an acid medium, its sorption onto the inner walls of the knotted reactor (KR) and elution with 40 μl of ethanol. An enhancement factor (EF) of 44 was obtained compared with the slope of the linear portion of the calibration curve before and after preconcentration The detection limit (3 s) was 0.008 μg l−1 As(III). The precision (RSD n = 11) was 4.5% at 0.1 μg l−1 As(III). The accuracy was demonstrated by total arsenic determination in certificed reference material, NASS-4, after pre-reduction of As(V) with L-cysteine 0.25% (m/v).

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A flow injection on-line sorption preconcentration system using a polytetrafluoroethylene (PTFE) knotted reactor was coupled with electrothermal atomic absorption spectrometry (ETAAS) to determine selectively As(III) in sea-water samples. Separation of arsenic inorganic species was achieved by the on-line formation of As(III)–pyrrolidine dithiocarbamate (PDC) complex in an acid medium, its sorption onto the inner walls of the knotted reactor (KR) and elution with 40 μl of ethanol. An enhancement factor (EF) of 44 was obtained compared with the slope of the linear portion of the calibration curve before and after preconcentration The detection limit (3 s) was 0.008 μg l−1 As(III). The precision (RSD n = 11) was 4.5% at 0.1 μg l−1 As(III). The accuracy was demonstrated by total arsenic determination in certificed reference material, NASS-4, after pre-reduction of As(V) with L-cysteine 0.25% (m/v).

Key concepts: Sorption, Chemistry, Detection limit, Atomic absorption spectroscopy, Analytical Chemistry (journal), Arsenic, Calibration curve, Elution

Related papers

Back to paper searchBrowse research topicsOriginal source
Flow on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry for selective As(iii) determination in sea-water samples — Research Paper | ScholarLens