2013Journal of Applied Animal ResearchRequires access

Comparison of fluoroscopic and radiographic imaging of long bones in healthy dogs

Shivali Sharma, Manjit Singh Kanwar, Sachin Tyagi, Imran Sheikh

Open publisher page 1 citations

Abstract

The purpose of this study was to describe observations based upon fluoroscopic examination of the long bones and to compare these results with the radiographic findings in healthy dogs. In general, the fluoroscopy employed significantly lesser kVp (kilo-voltage peak) settings and mA (milli-ampere) while still giving reasonably good images of all long bones having diagnostic importance. In the fluoroscopy, the kVp factors ranged from 45 to 55 with low mA values of 1.2 to 1.7. On the other hand, in radiography, the kVp values ranged from 55 to 65 at constant mAs (milli-ampere×seconds) of 10. Image magnification in fluoroscopy helped in close up-view but compromised bone size unlike the radiography. The contrast and details of the fluoroscopic images were not as good as the radiographic images, but most of the images were still sufficiently diagnostic. Furthermore, unlike fluoroscopy there was no limitation regarding the area of exposure during the radiographic examination of long bones of even large-sized dogs. In conclusion, although neither radiography nor fluoroscopy alone allowed a complete imaging of the long bones, the two techniques complemented one another well.

About this research paper

What this paper is about

The purpose of this study was to describe observations based upon fluoroscopic examination of the long bones and to compare these results with the radiographic findings in healthy dogs. In general, the fluoroscopy employed significantly lesser kVp (kilo-voltage peak) settings and mA (milli-ampere) while still giving reasonably good images of all long bones having diagnostic importance. In the fluoroscopy, the kVp factors ranged from 45 to 55 with low mA values of 1.2 to 1.7. On the other hand, in radiography, the kVp values ranged from 55 to 65 at constant mAs (milli-ampere×seconds) of 10. Image magnification in fluoroscopy helped in close up-view but compromised bone size unlike the radiography. The contrast and details of the fluoroscopic images were not as good as the radiographic images, but most of the images were still sufficiently diagnostic. Furthermore, unlike fluoroscopy there was no limitation regarding the area of exposure during the radiographic examination of long bones of even large-sized dogs. In conclusion, although neither radiography nor fluoroscopy alone allowed a complete imaging of the long bones, the two techniques complemented one another well.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to describe observations based upon fluoroscopic examination of the long bones and to compare these results with the radiographic findings in healthy dogs. In general, the fluoroscopy employed significantly lesser kVp (kilo-voltage peak) settings and mA (milli-ampere) while still giving reasonably good images of all long bones having diagnostic importance. In the fluoroscopy, the kVp factors ranged from 45 to 55 with low mA values of 1.2 to 1.7. On the other hand, in radiography, the kVp values ranged from 55 to 65 at constant mAs (milli-ampere×seconds) of 10. Image magnification in fluoroscopy helped in close up-view but compromised bone size unlike the radiography. The contrast and details of the fluoroscopic images were not as good as the radiographic images, but most of the images were still sufficiently diagnostic. Furthermore, unlike fluoroscopy there was no limitation regarding the area of exposure during the radiographic examination of long bones of even large-sized dogs. In conclusion, although neither radiography nor fluoroscopy alone allowed a complete imaging of the long bones, the two techniques complemented one another well.

Key concepts: Fluoroscopy, Radiography, Medicine, Magnification, Radiology, Nuclear medicine, Conventional radiography, Digital radiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of fluoroscopic and radiographic imaging of long bones in healthy dogs — Research Paper | ScholarLens