Pressure support ventilation during isoflurane anaesthesia

Shashi B. Bhatt, Po Tong Chui, Tony Gin, Y. H. Tam, T. E. Oh

Open publisher page 3 citations

Abstract

We have studied the respiratory effects of 5 and 10 cmH2O pressure support ventilation during anaesthesia with 1.5% end-tidal concentration of isoflurane in nine healthy, spontaneously breathing, adult patients. Some of the patients demonstrated an irregular respiratory pattern with periods of apnoea and we therefore went on to study a further seven patients with a continuous 500 s recording of airflow. Pressure support ventilation augmented mean (SD) tidal volume from 212 (56) ml to 360 (88) ml at 5 cmH2O and to 509 (108) ml at 10 cmH2O (n = 16, p < 0.05). Mean (SD) respiratory rate decreased from 26 (6) min-1 to 22 (6) min-1 at 5 cmH2O and 17 (5) min-1 at 10 cmH2O pressure support (n = 16, p < 0.05). Mean (SD) inspiratory work of breathing decreased from 1.77 (0.70) J. min-1 to 0.31 (0.36) J.min-1 at 5 cmH2O and 0.16 (0.26) J.min-1 at 10 cmH2O pressure support ventilation (n = 9, p < 0.05). Analysis of the respiratory rhythm in the second group of seven patients revealed an oscillating respiratory pattern in four patients at 5 cmH2O and six of the seven patients at 10 cmH2O pressure support ventilation. The metabolic advantage of the decreased work of breathing during pressure support ventilation during anaesthesia is unlikely to balance the disadvantage of an oscillating respiratory rhythm.

About this research paper

What this paper is about

We have studied the respiratory effects of 5 and 10 cmH2O pressure support ventilation during anaesthesia with 1.5% end-tidal concentration of isoflurane in nine healthy, spontaneously breathing, adult patients. Some of the patients demonstrated an irregular respiratory pattern with periods of apnoea and we therefore went on to study a further seven patients with a continuous 500 s recording of airflow. Pressure support ventilation augmented mean (SD) tidal volume from 212 (56) ml to 360 (88) ml at 5 cmH2O and to 509 (108) ml at 10 cmH2O (n = 16, p < 0.05). Mean (SD) respiratory rate decreased from 26 (6) min-1 to 22 (6) min-1 at 5 cmH2O and 17 (5) min-1 at 10 cmH2O pressure support (n = 16, p < 0.05). Mean (SD) inspiratory work of breathing decreased from 1.77 (0.70) J. min-1 to 0.31 (0.36) J.min-1 at 5 cmH2O and 0.16 (0.26) J.min-1 at 10 cmH2O pressure support ventilation (n = 9, p < 0.05). Analysis of the respiratory rhythm in the second group of seven patients revealed an oscillating respiratory pattern in four patients at 5 cmH2O and six of the seven patients at 10 cmH2O pressure support ventilation. The metabolic advantage of the decreased work of breathing during pressure support ventilation during anaesthesia is unlikely to balance the disadvantage of an oscillating respiratory rhythm.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have studied the respiratory effects of 5 and 10 cmH2O pressure support ventilation during anaesthesia with 1.5% end-tidal concentration of isoflurane in nine healthy, spontaneously breathing, adult patients. Some of the patients demonstrated an irregular respiratory pattern with periods of apnoea and we therefore went on to study a further seven patients with a continuous 500 s recording of airflow. Pressure support ventilation augmented mean (SD) tidal volume from 212 (56) ml to 360 (88) ml at 5 cmH2O and to 509 (108) ml at 10 cmH2O (n = 16, p < 0.05). Mean (SD) respiratory rate decreased from 26 (6) min-1 to 22 (6) min-1 at 5 cmH2O and 17 (5) min-1 at 10 cmH2O pressure support (n = 16, p < 0.05). Mean (SD) inspiratory work of breathing decreased from 1.77 (0.70) J. min-1 to 0.31 (0.36) J.min-1 at 5 cmH2O and 0.16 (0.26) J.min-1 at 10 cmH2O pressure support ventilation (n = 9, p < 0.05). Analysis of the respiratory rhythm in the second group of seven patients revealed an oscillating respiratory pattern in four patients at 5 cmH2O and six of the seven patients at 10 cmH2O pressure support ventilation. The metabolic advantage of the decreased work of breathing during pressure support ventilation during anaesthesia is unlikely to balance the disadvantage of an oscillating respiratory rhythm.

Key concepts: Medicine, Anesthesia, Ventilation (architecture), Tidal volume, Isoflurane, Pressure support ventilation, Respiratory system, Respiratory rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Pressure support ventilation during isoflurane anaesthesia — Research Paper | ScholarLens