1998•Pharmacology & ToxicologyRequires access

Aspects on Tail‐Flick, Hot‐Plate and Electrical Stimulation Tests for Morphine Antinociception

Marie Gårdmark, A. Urban Höglund, Margareta Hammarlund‐Udenaes

Open publisher page 77 citations

Abstract

The objective of this study was to compare the results of three nociceptive tests, tail-flick, hot-plate and electrical stimulation vocalisation, reflecting the responses from different sites in the CNS. A subcutaneous morphine dose (5 mg/kg) was administered to three parallel groups of rats in which the nociceptive response was measured by one of the three methods. The baseline decreased during the period of measurement for the hot-plate test, but remained stable for the other methods. The spinally mediated tail-flick response was more sensitive to the morphine effects as compared to the supraspinally mediated hot-plate and electrical stimulation vocalisation responses. The electrical stimulation vocalisation-test demonstrated more even effect-time profiles and less variability among the rats than did the tail-flick and the hot-plate methods. In the tail-flick group, 59% of the observations attained the cut-off latency at this morphine dose, leading to underestimation of the peak effect, the area under the effect curve (AUEC), and the variability among the rats. In the hot-plate group, 13% of the observations were at the cut-off latency, and 2% in the electrical stimulation vocalisation group. Different ways of presenting the data are discussed. In conclusion, the test selected for measuring the nociceptive response will influence the effect-time profile and subsequently any pharmacodynamic parameters describing it.

About this research paper

What this paper is about

The objective of this study was to compare the results of three nociceptive tests, tail-flick, hot-plate and electrical stimulation vocalisation, reflecting the responses from different sites in the CNS. A subcutaneous morphine dose (5 mg/kg) was administered to three parallel groups of rats in which the nociceptive response was measured by one of the three methods. The baseline decreased during the period of measurement for the hot-plate test, but remained stable for the other methods. The spinally mediated tail-flick response was more sensitive to the morphine effects as compared to the supraspinally mediated hot-plate and electrical stimulation vocalisation responses. The electrical stimulation vocalisation-test demonstrated more even effect-time profiles and less variability among the rats than did the tail-flick and the hot-plate methods. In the tail-flick group, 59% of the observations attained the cut-off latency at this morphine dose, leading to underestimation of the peak effect, the area under the effect curve (AUEC), and the variability among the rats. In the hot-plate group, 13% of the observations were at the cut-off latency, and 2% in the electrical stimulation vocalisation group. Different ways of presenting the data are discussed. In conclusion, the test selected for measuring the nociceptive response will influence the effect-time profile and subsequently any pharmacodynamic parameters describing it.

Why it matters

OpenAlex reports 77 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The objective of this study was to compare the results of three nociceptive tests, tail-flick, hot-plate and electrical stimulation vocalisation, reflecting the responses from different sites in the CNS. A subcutaneous morphine dose (5 mg/kg) was administered to three parallel groups of rats in which the nociceptive response was measured by one of the three methods. The baseline decreased during the period of measurement for the hot-plate test, but remained stable for the other methods. The spinally mediated tail-flick response was more sensitive to the morphine effects as compared to the supraspinally mediated hot-plate and electrical stimulation vocalisation responses. The electrical stimulation vocalisation-test demonstrated more even effect-time profiles and less variability among the rats than did the tail-flick and the hot-plate methods. In the tail-flick group, 59% of the observations attained the cut-off latency at this morphine dose, leading to underestimation of the peak effect, the area under the effect curve (AUEC), and the variability among the rats. In the hot-plate group, 13% of the observations were at the cut-off latency, and 2% in the electrical stimulation vocalisation group. Different ways of presenting the data are discussed. In conclusion, the test selected for measuring the nociceptive response will influence the effect-time profile and subsequently any pharmacodynamic parameters describing it.

Key concepts: Nociception, Hot plate, Tail flick test, Stimulation, Morphine, Hot plate test, Anesthesia, Latency (audio)

Related papers

Back to paper searchBrowse research topicsOriginal source
Aspects on Tail‐Flick, Hot‐Plate and Electrical Stimulation Tests for Morphine Antinociception — Research Paper | ScholarLens