2003•Clinical Chemistry and Laboratory Medicine (CCLM)Requires access

National External Quality Assessment Scheme for Lymphocyte Immunophenotyping in Belgium

Marjan Van Blerk, Michel Bernier, Xavier Bossuyt, Bernard Châtelain, Jean‐Luc D'hautcourt, Christian J. Demanet, Luc Kestens, Dirk Van Bockstaele, Tania Crucitti, Jean-Claude Libeer

Open publisher page 12 citations

Abstract

In 2000, the Belgian Scientific Institute of Public Health introduced a voluntary external quality assessment scheme for lymphocyte immunophenotyping. This paper provides an analysis of the first six surveys. Specimens consisted of fresh EDTA-anticoagulated whole blood and were sent by overnight mail. The 41 participants were surveyed for methodology and were asked to report white blood cell count, percentage of lymphocytes, and percentages and absolute numbers of CD3+, CD4+, CD8+, and CD19+ cells. Median intralaboratory coefficients of variation were 1.0, 1.3, 1.7, and 3.2% for CD3+, CD4+, CD8+, and CD19+ cell percentages, respectively. Interlaboratory variability was consistently lower than 6.5% for CD3+ and CD4+CD3+ cell percentages, and lower than 9.5% for CD8+CD3+ cell percentages. Median coefficients of variation for the absolute values were higher, ranging from 10.1% for CD4+CD3+ cells to 16.5% for CD19+ cells. The percentage of CD4+CD3+ and CD8+ CD3+ cells was in several samples significantly lower than the percentage of total CD4+ and CD8+ cells. The number of laboratories measuring total CD4+ and CD8+ cells decreased by 30% during the programme. Between-laboratory variability remained stable over time. Analysis of individual laboratory performance indicated that some laboratories markedly improved their results.

About this research paper

What this paper is about

In 2000, the Belgian Scientific Institute of Public Health introduced a voluntary external quality assessment scheme for lymphocyte immunophenotyping. This paper provides an analysis of the first six surveys. Specimens consisted of fresh EDTA-anticoagulated whole blood and were sent by overnight mail. The 41 participants were surveyed for methodology and were asked to report white blood cell count, percentage of lymphocytes, and percentages and absolute numbers of CD3+, CD4+, CD8+, and CD19+ cells. Median intralaboratory coefficients of variation were 1.0, 1.3, 1.7, and 3.2% for CD3+, CD4+, CD8+, and CD19+ cell percentages, respectively. Interlaboratory variability was consistently lower than 6.5% for CD3+ and CD4+CD3+ cell percentages, and lower than 9.5% for CD8+CD3+ cell percentages. Median coefficients of variation for the absolute values were higher, ranging from 10.1% for CD4+CD3+ cells to 16.5% for CD19+ cells. The percentage of CD4+CD3+ and CD8+ CD3+ cells was in several samples significantly lower than the percentage of total CD4+ and CD8+ cells. The number of laboratories measuring total CD4+ and CD8+ cells decreased by 30% during the programme. Between-laboratory variability remained stable over time. Analysis of individual laboratory performance indicated that some laboratories markedly improved their results.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In 2000, the Belgian Scientific Institute of Public Health introduced a voluntary external quality assessment scheme for lymphocyte immunophenotyping. This paper provides an analysis of the first six surveys. Specimens consisted of fresh EDTA-anticoagulated whole blood and were sent by overnight mail. The 41 participants were surveyed for methodology and were asked to report white blood cell count, percentage of lymphocytes, and percentages and absolute numbers of CD3+, CD4+, CD8+, and CD19+ cells. Median intralaboratory coefficients of variation were 1.0, 1.3, 1.7, and 3.2% for CD3+, CD4+, CD8+, and CD19+ cell percentages, respectively. Interlaboratory variability was consistently lower than 6.5% for CD3+ and CD4+CD3+ cell percentages, and lower than 9.5% for CD8+CD3+ cell percentages. Median coefficients of variation for the absolute values were higher, ranging from 10.1% for CD4+CD3+ cells to 16.5% for CD19+ cells. The percentage of CD4+CD3+ and CD8+ CD3+ cells was in several samples significantly lower than the percentage of total CD4+ and CD8+ cells. The number of laboratories measuring total CD4+ and CD8+ cells decreased by 30% during the programme. Between-laboratory variability remained stable over time. Analysis of individual laboratory performance indicated that some laboratories markedly improved their results.

Key concepts: Immunophenotyping, CD8, CD3, CD19, Lymphocyte, Immunology, Biology, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
National External Quality Assessment Scheme for Lymphocyte Immunophenotyping in Belgium — Research Paper | ScholarLens