1998Journal of AsthmaRequires access

A Study on the Clinical Equivalence and Patient Preference of Fluticasone Propionate 250 μg Twice Daily via the DiskusTM/AccuhalerTMInhaler or the DiskhalerTM* Inhaler in Adult Asthmatic Patients

Willem R. Pieters, Roland A. L. M. Stallaert, Jan M. Prins, A.P.M. Greefhorst, H G Bosman, R. Van Uffelen, A. J. M. Schreurs, J. L.M. van Helmond, P. G.M. Janssen, Martijn Akveld

Open publisher page 24 citations

Abstract

The Diskus/Accuhaler inhaler (D/A) is a new multidose powder inhaler, designed to deliver all asthma drugs. This study was carried out to establish clinical equivalence between FP 250 microg twice daily (b.i.d.) via the D/A and FP 250 microg b.i.d. via the current powder inhaler, the Diskhaler (DH). Also, device handling and patient preference for both devices were determined. This was a multicenter, randomized, double-blind, double-dummy, parallel-group study. Adult asthmatics (364, aged 18-79) requiring inhaled corticosteroids in a daily dosage of 400 microg up to and including 1000 microg and demonstrating a mean morning peak expiratory flow rate (PEFR) calculated from the last 7 days of the run-in of less than 85% of the response after salbutamol, a baseline forced expiratory volume in 1 sec (FEV1) between 50 and 90% of their predicted normal value, and an ability to correctly use both devices, were randomized to a 12-week treatment period. No statistically significant differences between the two devices were seen for mean morning PEFR (p = 0.76), mean evening PEFR (p = 0.88), median daytime and nighttime symptom score (p = 0.57 and p = 0.47), median percentage of rescue-free days and nights (p = 0.43 and p = 0.24), and clinic visit lung function. No differences in the safety profile of FP were seen. Patients found the D/A easier to use and easier with respect to assessing the number of doses remaining (both p < 0.001). Sixty-five percent of the patients expressed an overall preference for the D/A over the DH (p < 0.001). The results show that FP 250 microg b.i.d. via the D/A is clinically equivalent to delivery via the DH. Both treatments proved to be equally safe and were well tolerated. The D/A was easier to use and patients preferred the D/A over the DH.

About this research paper

What this paper is about

The Diskus/Accuhaler inhaler (D/A) is a new multidose powder inhaler, designed to deliver all asthma drugs. This study was carried out to establish clinical equivalence between FP 250 microg twice daily (b.i.d.) via the D/A and FP 250 microg b.i.d. via the current powder inhaler, the Diskhaler (DH). Also, device handling and patient preference for both devices were determined. This was a multicenter, randomized, double-blind, double-dummy, parallel-group study. Adult asthmatics (364, aged 18-79) requiring inhaled corticosteroids in a daily dosage of 400 microg up to and including 1000 microg and demonstrating a mean morning peak expiratory flow rate (PEFR) calculated from the last 7 days of the run-in of less than 85% of the response after salbutamol, a baseline forced expiratory volume in 1 sec (FEV1) between 50 and 90% of their predicted normal value, and an ability to correctly use both devices, were randomized to a 12-week treatment period. No statistically significant differences between the two devices were seen for mean morning PEFR (p = 0.76), mean evening PEFR (p = 0.88), median daytime and nighttime symptom score (p = 0.57 and p = 0.47), median percentage of rescue-free days and nights (p = 0.43 and p = 0.24), and clinic visit lung function. No differences in the safety profile of FP were seen. Patients found the D/A easier to use and easier with respect to assessing the number of doses remaining (both p < 0.001). Sixty-five percent of the patients expressed an overall preference for the D/A over the DH (p < 0.001). The results show that FP 250 microg b.i.d. via the D/A is clinically equivalent to delivery via the DH. Both treatments proved to be equally safe and were well tolerated. The D/A was easier to use and patients preferred the D/A over the DH.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Diskus/Accuhaler inhaler (D/A) is a new multidose powder inhaler, designed to deliver all asthma drugs. This study was carried out to establish clinical equivalence between FP 250 microg twice daily (b.i.d.) via the D/A and FP 250 microg b.i.d. via the current powder inhaler, the Diskhaler (DH). Also, device handling and patient preference for both devices were determined. This was a multicenter, randomized, double-blind, double-dummy, parallel-group study. Adult asthmatics (364, aged 18-79) requiring inhaled corticosteroids in a daily dosage of 400 microg up to and including 1000 microg and demonstrating a mean morning peak expiratory flow rate (PEFR) calculated from the last 7 days of the run-in of less than 85% of the response after salbutamol, a baseline forced expiratory volume in 1 sec (FEV1) between 50 and 90% of their predicted normal value, and an ability to correctly use both devices, were randomized to a 12-week treatment period. No statistically significant differences between the two devices were seen for mean morning PEFR (p = 0.76), mean evening PEFR (p = 0.88), median daytime and nighttime symptom score (p = 0.57 and p = 0.47), median percentage of rescue-free days and nights (p = 0.43 and p = 0.24), and clinic visit lung function. No differences in the safety profile of FP were seen. Patients found the D/A easier to use and easier with respect to assessing the number of doses remaining (both p < 0.001). Sixty-five percent of the patients expressed an overall preference for the D/A over the DH (p < 0.001). The results show that FP 250 microg b.i.d. via the D/A is clinically equivalent to delivery via the DH. Both treatments proved to be equally safe and were well tolerated. The D/A was easier to use and patients preferred the D/A over the DH.

Key concepts: Fluticasone propionate, Inhaler, Morning, Medicine, Asthma, Salbutamol, Evening, Randomized controlled trial

Related papers

Back to paper searchBrowse research topicsOriginal source
A Study on the Clinical Equivalence and Patient Preference of Fluticasone Propionate 250 μg Twice Daily via the DiskusTM/AccuhalerTMInhaler or the DiskhalerTM* Inhaler in Adult Asthmatic Patients — Research Paper | ScholarLens