1999Physics in Medicine and BiologyRequires access

The importance of radiometer angular response for ultraviolet phototherapy dosimetry

C J Martin, G. D. Currie, S.D. Pye

Open publisher page 23 citations

Abstract

The influence of the angular response of radiometer probes on measurements of irradiance in ultraviolet phototherapy has been studied. Irradiance measurements were made using nine ultraviolet (UV) radiometers employed by phototherapy centres in Scotland and Northern Ireland, and compared with measurements made using two spectroradiometers. The light sources used were UVB TL01 fluorescent lamps, arranged in different geometries. Irradiances within TL01 whole body treatment cabinets were assessed based on a comparison with one of the spectroradiometers. The results show variations of 50% in cabinet irradiance measurements made by different radiometers, even when they were calibrated using the same source geometry and spectroradiometer. Differences in radiometer probe design and construction lead to an under- or over-response at angles of incidence greater than zero. Angular responses of different probes were assessed using banks of fluorescent lamps. The differences found are large enough to account for the variations in measurements of cabinet irradiance. The variations in irradiance measurements are significant in terms of planning and monitoring patient exposure during TL01 phototherapy. Accurate dosimetry can only be achieved if radiometer probes have a good cosine response and recommendations are made for better calibration techniques.

About this research paper

What this paper is about

The influence of the angular response of radiometer probes on measurements of irradiance in ultraviolet phototherapy has been studied. Irradiance measurements were made using nine ultraviolet (UV) radiometers employed by phototherapy centres in Scotland and Northern Ireland, and compared with measurements made using two spectroradiometers. The light sources used were UVB TL01 fluorescent lamps, arranged in different geometries. Irradiances within TL01 whole body treatment cabinets were assessed based on a comparison with one of the spectroradiometers. The results show variations of 50% in cabinet irradiance measurements made by different radiometers, even when they were calibrated using the same source geometry and spectroradiometer. Differences in radiometer probe design and construction lead to an under- or over-response at angles of incidence greater than zero. Angular responses of different probes were assessed using banks of fluorescent lamps. The differences found are large enough to account for the variations in measurements of cabinet irradiance. The variations in irradiance measurements are significant in terms of planning and monitoring patient exposure during TL01 phototherapy. Accurate dosimetry can only be achieved if radiometer probes have a good cosine response and recommendations are made for better calibration techniques.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The influence of the angular response of radiometer probes on measurements of irradiance in ultraviolet phototherapy has been studied. Irradiance measurements were made using nine ultraviolet (UV) radiometers employed by phototherapy centres in Scotland and Northern Ireland, and compared with measurements made using two spectroradiometers. The light sources used were UVB TL01 fluorescent lamps, arranged in different geometries. Irradiances within TL01 whole body treatment cabinets were assessed based on a comparison with one of the spectroradiometers. The results show variations of 50% in cabinet irradiance measurements made by different radiometers, even when they were calibrated using the same source geometry and spectroradiometer. Differences in radiometer probe design and construction lead to an under- or over-response at angles of incidence greater than zero. Angular responses of different probes were assessed using banks of fluorescent lamps. The differences found are large enough to account for the variations in measurements of cabinet irradiance. The variations in irradiance measurements are significant in terms of planning and monitoring patient exposure during TL01 phototherapy. Accurate dosimetry can only be achieved if radiometer probes have a good cosine response and recommendations are made for better calibration techniques.

Key concepts: Irradiance, Radiometer, Spectroradiometer, Remote sensing, Ultraviolet, Optics, Environmental science, Radiation

Related papers

Back to paper searchBrowse research topicsOriginal source
The importance of radiometer angular response for ultraviolet phototherapy dosimetry — Research Paper | ScholarLens