2010HandOpen access

Traumatic Closed Index Extensor Tendon Rupture at the Musclotendinous Junction: A Report of Two Cases

Shingo Komura, Tatsuo Yokoi, Hidehiko Nonomura

Open full text 11 citations

Abstract

This report describes two cases of traumatic closed index extensor tendon rupture at the musclotendinous junction. Both patients were injured when their work gloves were caught in the revolving parts of machines, and both were treated surgically. One of the patients completely ruptured the index extensor digitorum communis (EDC) and the extensor indicis proprius (EIP) tendons at the musclotendinous junction of dorsal forearm. In this patient, the distal stump of the index EDC tendon was sutured to the middle EDC tendon in an end-to-side juncture. The other patient completely ruptured the EIP tendon and partially ruptured the index EDC tendon at the musclotendinous junction. In this patient, tendon transfer of the extensor digiti minimi (EDM) to the EIP tendon and plication of the index EDC tendon were performed. In both cases, surgical intervention enabled the patients to extend their index fingers almost normally; however, the former complained of inability to extend his index finger independently. Tendon transfer of the EDM in cases of index extensor tendon rupture at the musclotendinous junction is a good method to restore ability to independently extend the index finger. However, consideration should be given to anatomical variation in the little finger. The EDC tendon is sometimes absent leaving the EDM tendon as the only extensor tendon to the little finger.

About this research paper

What this paper is about

This report describes two cases of traumatic closed index extensor tendon rupture at the musclotendinous junction. Both patients were injured when their work gloves were caught in the revolving parts of machines, and both were treated surgically. One of the patients completely ruptured the index extensor digitorum communis (EDC) and the extensor indicis proprius (EIP) tendons at the musclotendinous junction of dorsal forearm. In this patient, the distal stump of the index EDC tendon was sutured to the middle EDC tendon in an end-to-side juncture. The other patient completely ruptured the EIP tendon and partially ruptured the index EDC tendon at the musclotendinous junction. In this patient, tendon transfer of the extensor digiti minimi (EDM) to the EIP tendon and plication of the index EDC tendon were performed. In both cases, surgical intervention enabled the patients to extend their index fingers almost normally; however, the former complained of inability to extend his index finger independently. Tendon transfer of the EDM in cases of index extensor tendon rupture at the musclotendinous junction is a good method to restore ability to independently extend the index finger. However, consideration should be given to anatomical variation in the little finger. The EDC tendon is sometimes absent leaving the EDM tendon as the only extensor tendon to the little finger.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This report describes two cases of traumatic closed index extensor tendon rupture at the musclotendinous junction. Both patients were injured when their work gloves were caught in the revolving parts of machines, and both were treated surgically. One of the patients completely ruptured the index extensor digitorum communis (EDC) and the extensor indicis proprius (EIP) tendons at the musclotendinous junction of dorsal forearm. In this patient, the distal stump of the index EDC tendon was sutured to the middle EDC tendon in an end-to-side juncture. The other patient completely ruptured the EIP tendon and partially ruptured the index EDC tendon at the musclotendinous junction. In this patient, tendon transfer of the extensor digiti minimi (EDM) to the EIP tendon and plication of the index EDC tendon were performed. In both cases, surgical intervention enabled the patients to extend their index fingers almost normally; however, the former complained of inability to extend his index finger independently. Tendon transfer of the EDM in cases of index extensor tendon rupture at the musclotendinous junction is a good method to restore ability to independently extend the index finger. However, consideration should be given to anatomical variation in the little finger. The EDC tendon is sometimes absent leaving the EDM tendon as the only extensor tendon to the little finger.

Key concepts: Tendon, Medicine, Index finger, Extensor Digitorum Communis, Tendon transfer, Anatomy, Surgery, Tendon rupture

Related papers

Back to paper searchBrowse research topicsOriginal source
Traumatic Closed Index Extensor Tendon Rupture at the Musclotendinous Junction: A Report of Two Cases — Research Paper | ScholarLens