2011Ironmaking & Steelmaking Processes Products and ApplicationsRequires access

Optimal control of secondary cooling for medium thickness slab continuous casting

X-Y Wang, Q Liu, Bo Wang, X Wang, J-S Qing, Z-G Hu, Yanhui Sun

Open publisher page 25 citations

Abstract

A software to simulate the solidification, heat transfer and water flowrate distribution in slab continuous casting was developed by establishing a mathematical model for the heat transfer and solidification in medium thickness slab casting. This model was validated by pin shooting and surface temperature measurement experiments. A reasonable target surface control temperature was found by testing the high temperature mechanical properties of Nb bearing ship plate steel, and then the water flowrate of each loop of the secondary cooling zone was determined by the software. The influence of uneven secondary cooling in the slab width direction on the quality of the slab was also investigated, which provided data for the optimisation of the secondary cooling of the slab caster. On the basis of the above research, an optimisation scheme for a secondary cooling system was proposed. Experimental results showed that the quality of the slab was significantly improved after optimisation. The centreline macrosegregation was reduced, and the ratio of equiaxed grains was increased by 3·18%. In addition, the transverse cracking of the slab was almost eliminated.

About this research paper

What this paper is about

A software to simulate the solidification, heat transfer and water flowrate distribution in slab continuous casting was developed by establishing a mathematical model for the heat transfer and solidification in medium thickness slab casting. This model was validated by pin shooting and surface temperature measurement experiments. A reasonable target surface control temperature was found by testing the high temperature mechanical properties of Nb bearing ship plate steel, and then the water flowrate of each loop of the secondary cooling zone was determined by the software. The influence of uneven secondary cooling in the slab width direction on the quality of the slab was also investigated, which provided data for the optimisation of the secondary cooling of the slab caster. On the basis of the above research, an optimisation scheme for a secondary cooling system was proposed. Experimental results showed that the quality of the slab was significantly improved after optimisation. The centreline macrosegregation was reduced, and the ratio of equiaxed grains was increased by 3·18%. In addition, the transverse cracking of the slab was almost eliminated.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A software to simulate the solidification, heat transfer and water flowrate distribution in slab continuous casting was developed by establishing a mathematical model for the heat transfer and solidification in medium thickness slab casting. This model was validated by pin shooting and surface temperature measurement experiments. A reasonable target surface control temperature was found by testing the high temperature mechanical properties of Nb bearing ship plate steel, and then the water flowrate of each loop of the secondary cooling zone was determined by the software. The influence of uneven secondary cooling in the slab width direction on the quality of the slab was also investigated, which provided data for the optimisation of the secondary cooling of the slab caster. On the basis of the above research, an optimisation scheme for a secondary cooling system was proposed. Experimental results showed that the quality of the slab was significantly improved after optimisation. The centreline macrosegregation was reduced, and the ratio of equiaxed grains was increased by 3·18%. In addition, the transverse cracking of the slab was almost eliminated.

Key concepts: Slab, Continuous casting, Materials science, Heat transfer, Water cooling, Caster, Casting, Equiaxed crystals

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimal control of secondary cooling for medium thickness slab continuous casting — Research Paper | ScholarLens