2004Clinical Orthopaedics and Related ResearchRequires access

Accurate Measurement of Ankle Range of Motion after Total Ankle Arthroplasty

J. Chris Coetzee, Michael D. Castro

Open publisher page 122 citations

Abstract

There is no standardized method reported in the literature to measure ROM of the ankle after a total ankle arthroplasty, which limits the possibility to compare results from the various ankle designs. It seems that most of the measurements are a combination of ankle and midfoot motion, not the tibiotalar joint. A protocol was developed to accurately measure the true tibiotalar and midfoot motion before and after an ankle replacement. Lateral radiographs were taken of the ankle with the patient in a weightbearing position, and measurements were done along fixed landmarks. In this study, the tibiotalar, midfoot, and combined ROM were measured preoperative and 1 year postoperative in a standardized, reproducible fashion. The preoperative tibiotalar ROM was 18.5 degrees and combined ankle and midfoot motion 25.1 degrees. The true tibiotalar motion after an Agility total ankle arthroplasty was 23.4 degrees, and the combined ankle and midfoot motion was 31.3 degrees. The average improvement in ROM in the tibiotalar joint was approximately 5 degrees, and combined ROM was 6.1 degrees. Preoperative ROM proved to be the main factor determining the eventual postoperative ROM. It is possible to accurately measure the true ankle and the midfoot motion and those measurements should be used when reporting on the results of ankle replacements. Total ankle arthroplasty resulted in a statistically significant, but clinically less than expected, increase in ROM.

About this research paper

What this paper is about

There is no standardized method reported in the literature to measure ROM of the ankle after a total ankle arthroplasty, which limits the possibility to compare results from the various ankle designs. It seems that most of the measurements are a combination of ankle and midfoot motion, not the tibiotalar joint. A protocol was developed to accurately measure the true tibiotalar and midfoot motion before and after an ankle replacement. Lateral radiographs were taken of the ankle with the patient in a weightbearing position, and measurements were done along fixed landmarks. In this study, the tibiotalar, midfoot, and combined ROM were measured preoperative and 1 year postoperative in a standardized, reproducible fashion. The preoperative tibiotalar ROM was 18.5 degrees and combined ankle and midfoot motion 25.1 degrees. The true tibiotalar motion after an Agility total ankle arthroplasty was 23.4 degrees, and the combined ankle and midfoot motion was 31.3 degrees. The average improvement in ROM in the tibiotalar joint was approximately 5 degrees, and combined ROM was 6.1 degrees. Preoperative ROM proved to be the main factor determining the eventual postoperative ROM. It is possible to accurately measure the true ankle and the midfoot motion and those measurements should be used when reporting on the results of ankle replacements. Total ankle arthroplasty resulted in a statistically significant, but clinically less than expected, increase in ROM.

Why it matters

OpenAlex reports 122 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

There is no standardized method reported in the literature to measure ROM of the ankle after a total ankle arthroplasty, which limits the possibility to compare results from the various ankle designs. It seems that most of the measurements are a combination of ankle and midfoot motion, not the tibiotalar joint. A protocol was developed to accurately measure the true tibiotalar and midfoot motion before and after an ankle replacement. Lateral radiographs were taken of the ankle with the patient in a weightbearing position, and measurements were done along fixed landmarks. In this study, the tibiotalar, midfoot, and combined ROM were measured preoperative and 1 year postoperative in a standardized, reproducible fashion. The preoperative tibiotalar ROM was 18.5 degrees and combined ankle and midfoot motion 25.1 degrees. The true tibiotalar motion after an Agility total ankle arthroplasty was 23.4 degrees, and the combined ankle and midfoot motion was 31.3 degrees. The average improvement in ROM in the tibiotalar joint was approximately 5 degrees, and combined ROM was 6.1 degrees. Preoperative ROM proved to be the main factor determining the eventual postoperative ROM. It is possible to accurately measure the true ankle and the midfoot motion and those measurements should be used when reporting on the results of ankle replacements. Total ankle arthroplasty resulted in a statistically significant, but clinically less than expected, increase in ROM.

Key concepts: Ankle, Medicine, Range of motion, Ankle replacement, Orthodontics, Arthroplasty, Radiography, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Accurate Measurement of Ankle Range of Motion after Total Ankle Arthroplasty — Research Paper | ScholarLens