2013Journal of Orthopaedic and Sports Physical TherapyRequires access

Reliability and Validity of the Dutch Version of the International Physical Activity Questionnaire in Patients After Total Hip Arthroplasty or Total Knee Arthroplasty

Tim Blikman, Martin J. Stevens, Sjoerd K. Bulstra, Inge van den Akker‐Scheek, Inge H. F. Reininga

Open publisher page 38 citations

Abstract

STUDY DESIGN: Psychometric assessment. OBJECTIVES: To determine test-retest reliability and concurrent validity of the International Physical Activity Questionnaire (IPAQ) in patients after total hip arthroplasty or total knee arthroplasty. BACKGROUND: Despite recognized benefits of regular physical activity, little is known about the physical activity level of patients after total hip arthroplasty or total knee arthroplasty. None of the currently used questionnaires is internationally accepted. The IPAQ tries to address this problem, but its validity and reliability in those who have had a total hip arthroplasty or total knee arthroplasty are unknown. METHODS: Forty-four patients completed the IPAQ (short and long forms) twice. Test-retest reliability was assessed by Spearman correlation coefficients (r) and intraclass correlation coefficients. Additionally, standard error of measurement and minimal detectable change were calculated. Concurrent validity was determined by an accelerometer. Spearman correlation coefficients were calculated between IPAQ scores and accelerometer data. Bland-Altman analyses were performed for both reliability and validity. RESULTS: Fair to good correlation coefficients were found for test-retest reliability of the total and activity scores (r = 0.49-0.81, intraclass correlation coefficient = 0.27-0.71). Standard error of measurement and minimal detectable change were large. For concurrent validity, weak to moderate correlation coefficients were found for total and activity scores (r = -0.07 to 0.54). Systematic bias was found between the IPAQ and accelerometer data, with higher scores on the IPAQ. CONCLUSION: Overall, the IPAQ showed fair reliability and weak concurrent validity. These results are in line with previous studies of the reliability and validity of the IPAQ. Due to systematic bias and large standard error of measurement and minimal detectable change, the IPAQ may only be suitable for intergroup comparisons.

About this research paper

What this paper is about

STUDY DESIGN: Psychometric assessment. OBJECTIVES: To determine test-retest reliability and concurrent validity of the International Physical Activity Questionnaire (IPAQ) in patients after total hip arthroplasty or total knee arthroplasty. BACKGROUND: Despite recognized benefits of regular physical activity, little is known about the physical activity level of patients after total hip arthroplasty or total knee arthroplasty. None of the currently used questionnaires is internationally accepted. The IPAQ tries to address this problem, but its validity and reliability in those who have had a total hip arthroplasty or total knee arthroplasty are unknown. METHODS: Forty-four patients completed the IPAQ (short and long forms) twice. Test-retest reliability was assessed by Spearman correlation coefficients (r) and intraclass correlation coefficients. Additionally, standard error of measurement and minimal detectable change were calculated. Concurrent validity was determined by an accelerometer. Spearman correlation coefficients were calculated between IPAQ scores and accelerometer data. Bland-Altman analyses were performed for both reliability and validity. RESULTS: Fair to good correlation coefficients were found for test-retest reliability of the total and activity scores (r = 0.49-0.81, intraclass correlation coefficient = 0.27-0.71). Standard error of measurement and minimal detectable change were large. For concurrent validity, weak to moderate correlation coefficients were found for total and activity scores (r = -0.07 to 0.54). Systematic bias was found between the IPAQ and accelerometer data, with higher scores on the IPAQ. CONCLUSION: Overall, the IPAQ showed fair reliability and weak concurrent validity. These results are in line with previous studies of the reliability and validity of the IPAQ. Due to systematic bias and large standard error of measurement and minimal detectable change, the IPAQ may only be suitable for intergroup comparisons.

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

STUDY DESIGN: Psychometric assessment. OBJECTIVES: To determine test-retest reliability and concurrent validity of the International Physical Activity Questionnaire (IPAQ) in patients after total hip arthroplasty or total knee arthroplasty. BACKGROUND: Despite recognized benefits of regular physical activity, little is known about the physical activity level of patients after total hip arthroplasty or total knee arthroplasty. None of the currently used questionnaires is internationally accepted. The IPAQ tries to address this problem, but its validity and reliability in those who have had a total hip arthroplasty or total knee arthroplasty are unknown. METHODS: Forty-four patients completed the IPAQ (short and long forms) twice. Test-retest reliability was assessed by Spearman correlation coefficients (r) and intraclass correlation coefficients. Additionally, standard error of measurement and minimal detectable change were calculated. Concurrent validity was determined by an accelerometer. Spearman correlation coefficients were calculated between IPAQ scores and accelerometer data. Bland-Altman analyses were performed for both reliability and validity. RESULTS: Fair to good correlation coefficients were found for test-retest reliability of the total and activity scores (r = 0.49-0.81, intraclass correlation coefficient = 0.27-0.71). Standard error of measurement and minimal detectable change were large. For concurrent validity, weak to moderate correlation coefficients were found for total and activity scores (r = -0.07 to 0.54). Systematic bias was found between the IPAQ and accelerometer data, with higher scores on the IPAQ. CONCLUSION: Overall, the IPAQ showed fair reliability and weak concurrent validity. These results are in line with previous studies of the reliability and validity of the IPAQ. Due to systematic bias and large standard error of measurement and minimal detectable change, the IPAQ may only be suitable for intergroup comparisons.

Key concepts: Intraclass correlation, Concurrent validity, Physical therapy, Reliability (semiconductor), Criterion validity, Standard error, Arthroplasty, Validity

Related papers

Back to paper searchBrowse research topicsOriginal source
Reliability and Validity of the Dutch Version of the International Physical Activity Questionnaire in Patients After Total Hip Arthroplasty or Total Knee Arthroplasty — Research Paper | ScholarLens