1994•Journal of Cerebral Blood Flow & MetabolismOpen access

Acetazolamide Reactivity on 123 I-IMP Single Photon Emission Computed Tomography in Patients with Major Cerebral Artery Occlusive Disease: Correlation with Positron Emission Tomography Parameters

Teruyuki Hirano, Kazuo Minematsu, Yasuhiro Hasegawa, Yutaka Tanaka, Kohei Hayashida, Takenori Yamaguchi

Open full text 149 citations

Abstract

Single photon emission computed tomography (SPECT) with acetazolamide challenge has increasingly been used for evaluating hemodynamic reserve in stroke patients. The accuracy of this test, however, has not been validated with positron emission tomography (PET). In 14 patients who had occlusive disease of the internal carotid artery or the trunk of the middle cerebral artery (MCA) with minimal or no infarction on computed tomography (CT) and magnetic resonance imaging (MRI), we compared acetazolamide reactivity on SPECT with N-isopropyl-p-[123I]-iodoamphetamine to hemodynamic parameters determined with gas inhalation labeled 15O steady-state PET studies. The asymmetry index (AI)--i.e., the percentage of the activity rate of the ischemic MCA territory versus the contralateral one, was determined by SPECT. Acetazolamide reactivity expressed as delta AI, or change in AI after acetazolamide challenge, was significantly lower in seven patients than -8.4%, the lower limit of the 95% confidence interval for the normal reactivity. Values of ipsilateral CBF, cerebral blood volume (CBV)/CBF, and oxygen extraction fraction (OEF) and contralateral OEF were significantly different between patients with normal and reduced acetazolamide reactivity. Values of delta AI were correlated with OEF (r = -0.87; p < 0.001) and CBV/CBF (r = -0.56; p < 0.05). All patients with OEF > 0.52, the mean + 2 SD calculated from five normal volunteers, also had reduced acetazolamide reactivity, while the patients with normal OEF values had normal reactivity. The present study has demonstrated that SPECT studies with an acetazolamide challenge can detect the Stage II hemodynamic failure.

Open-access reader

About this research paper

What this paper is about

Single photon emission computed tomography (SPECT) with acetazolamide challenge has increasingly been used for evaluating hemodynamic reserve in stroke patients. The accuracy of this test, however, has not been validated with positron emission tomography (PET). In 14 patients who had occlusive disease of the internal carotid artery or the trunk of the middle cerebral artery (MCA) with minimal or no infarction on computed tomography (CT) and magnetic resonance imaging (MRI), we compared acetazolamide reactivity on SPECT with N-isopropyl-p-[123I]-iodoamphetamine to hemodynamic parameters determined with gas inhalation labeled 15O steady-state PET studies. The asymmetry index (AI)--i.e., the percentage of the activity rate of the ischemic MCA territory versus the contralateral one, was determined by SPECT. Acetazolamide reactivity expressed as delta AI, or change in AI after acetazolamide challenge, was significantly lower in seven patients than -8.4%, the lower limit of the 95% confidence interval for the normal reactivity. Values of ipsilateral CBF, cerebral blood volume (CBV)/CBF, and oxygen extraction fraction (OEF) and contralateral OEF were significantly different between patients with normal and reduced acetazolamide reactivity. Values of delta AI were correlated with OEF (r = -0.87; p < 0.001) and CBV/CBF (r = -0.56; p < 0.05). All patients with OEF > 0.52, the mean + 2 SD calculated from five normal volunteers, also had reduced acetazolamide reactivity, while the patients with normal OEF values had normal reactivity. The present study has demonstrated that SPECT studies with an acetazolamide challenge can detect the Stage II hemodynamic failure.

Why it matters

OpenAlex reports 149 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Single photon emission computed tomography (SPECT) with acetazolamide challenge has increasingly been used for evaluating hemodynamic reserve in stroke patients. The accuracy of this test, however, has not been validated with positron emission tomography (PET). In 14 patients who had occlusive disease of the internal carotid artery or the trunk of the middle cerebral artery (MCA) with minimal or no infarction on computed tomography (CT) and magnetic resonance imaging (MRI), we compared acetazolamide reactivity on SPECT with N-isopropyl-p-[123I]-iodoamphetamine to hemodynamic parameters determined with gas inhalation labeled 15O steady-state PET studies. The asymmetry index (AI)--i.e., the percentage of the activity rate of the ischemic MCA territory versus the contralateral one, was determined by SPECT. Acetazolamide reactivity expressed as delta AI, or change in AI after acetazolamide challenge, was significantly lower in seven patients than -8.4%, the lower limit of the 95% confidence interval for the normal reactivity. Values of ipsilateral CBF, cerebral blood volume (CBV)/CBF, and oxygen extraction fraction (OEF) and contralateral OEF were significantly different between patients with normal and reduced acetazolamide reactivity. Values of delta AI were correlated with OEF (r = -0.87; p < 0.001) and CBV/CBF (r = -0.56; p < 0.05). All patients with OEF > 0.52, the mean + 2 SD calculated from five normal volunteers, also had reduced acetazolamide reactivity, while the patients with normal OEF values had normal reactivity. The present study has demonstrated that SPECT studies with an acetazolamide challenge can detect the Stage II hemodynamic failure.

Key concepts: Acetazolamide, Cerebral blood flow, Emission computed tomography, Single-photon emission computed tomography, Positron emission tomography, Medicine, Nuclear medicine, Hemodynamics

Related papers

Back to paper searchBrowse research topicsOriginal source
Acetazolamide Reactivity on 123 I-IMP Single Photon Emission Computed Tomography in Patients with Major Cerebral Artery Occlusive Disease: Correlation with Positron Emission Tomography Parameters — Research Paper | ScholarLens