2011Advanced materials researchOpen access

The Numerical Study on the Environmentally Sustainable System - Ground-Source Heat Pump System

Su Fen Li, Yan Shang, Di Chen

Open full text 3 citations

Abstract

In this paper, the coupled thermal conduction and groundwater advection heat transfer model was developed according to the heat-transfer process between the heat exchanger underground and its ambient soil. Soil was considered as saturated porous medium. The paper analyzed that the influence of different inlet flow rate, inlet water temperature, and backfill material on the soil temperature field and heat exchange rate, compared the double U-tube and the single U-tube in numerical simulation. The results show that the enhancing of soil thermal conductivity, inlet water temperature and inlet water flow rate leads to the increase of the heat exchange rate of U tube heat exchanger, and the influence on the double U tube is relativity small. In addition, the heat exchange characteristic of the double U tube is superior to the single U tube. The result has guiding significance to the intermittent operation of the ground source heat pump.

About this research paper

What this paper is about

In this paper, the coupled thermal conduction and groundwater advection heat transfer model was developed according to the heat-transfer process between the heat exchanger underground and its ambient soil. Soil was considered as saturated porous medium. The paper analyzed that the influence of different inlet flow rate, inlet water temperature, and backfill material on the soil temperature field and heat exchange rate, compared the double U-tube and the single U-tube in numerical simulation. The results show that the enhancing of soil thermal conductivity, inlet water temperature and inlet water flow rate leads to the increase of the heat exchange rate of U tube heat exchanger, and the influence on the double U tube is relativity small. In addition, the heat exchange characteristic of the double U tube is superior to the single U tube. The result has guiding significance to the intermittent operation of the ground source heat pump.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, the coupled thermal conduction and groundwater advection heat transfer model was developed according to the heat-transfer process between the heat exchanger underground and its ambient soil. Soil was considered as saturated porous medium. The paper analyzed that the influence of different inlet flow rate, inlet water temperature, and backfill material on the soil temperature field and heat exchange rate, compared the double U-tube and the single U-tube in numerical simulation. The results show that the enhancing of soil thermal conductivity, inlet water temperature and inlet water flow rate leads to the increase of the heat exchange rate of U tube heat exchanger, and the influence on the double U tube is relativity small. In addition, the heat exchange characteristic of the double U tube is superior to the single U tube. The result has guiding significance to the intermittent operation of the ground source heat pump.

Key concepts: Inlet, Heat pump, Heat exchanger, Thermal conduction, Heat transfer, Mechanics, Materials science, Shell and tube heat exchanger

Related papers

Back to paper searchBrowse research topicsOriginal source
The Numerical Study on the Environmentally Sustainable System - Ground-Source Heat Pump System — Research Paper | ScholarLens