2009Ophthalmic ResearchRequires access

Optimal Pupil Diameter for Scheimpflug Slit Image Photography of the Lens in Man

Lisa Cheeks, Robert W. Summerer, Keith Green

Open publisher page 3 citations

Abstract

Densitometric analysis of Scheimpflug photography of the lens has been examined as a function of pupil diameter in normal volunteers. On the basis of both the length of the lens waveform and the integral area under the curve of the lens waveform, there is a critical pupil diameter above which the waveform is unchanged. Below this critical diameter the waveform becomes distorted by shortening and a change in shape. The critical pupil diameter is between 6 and 6.5 mm. This result is of importance either in longitudinal studies, where the pupil diameter may not be reproducible, or in studies where other drugs are used which may prevent full pupil dilatation.

About this research paper

What this paper is about

Densitometric analysis of Scheimpflug photography of the lens has been examined as a function of pupil diameter in normal volunteers. On the basis of both the length of the lens waveform and the integral area under the curve of the lens waveform, there is a critical pupil diameter above which the waveform is unchanged. Below this critical diameter the waveform becomes distorted by shortening and a change in shape. The critical pupil diameter is between 6 and 6.5 mm. This result is of importance either in longitudinal studies, where the pupil diameter may not be reproducible, or in studies where other drugs are used which may prevent full pupil dilatation.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Densitometric analysis of Scheimpflug photography of the lens has been examined as a function of pupil diameter in normal volunteers. On the basis of both the length of the lens waveform and the integral area under the curve of the lens waveform, there is a critical pupil diameter above which the waveform is unchanged. Below this critical diameter the waveform becomes distorted by shortening and a change in shape. The critical pupil diameter is between 6 and 6.5 mm. This result is of importance either in longitudinal studies, where the pupil diameter may not be reproducible, or in studies where other drugs are used which may prevent full pupil dilatation.

Key concepts: Scheimpflug principle, Pupil, Lens (geology), Optics, Pupil function, Slit, Waveform, Entrance pupil

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimal Pupil Diameter for Scheimpflug Slit Image Photography of the Lens in Man — Research Paper | ScholarLens