A New Sensitive Radioimmunoassay for Plasma Arginine Vasopressin
Patricia Rooke, P. H. Baylis
Abstract
Patricia Rooke, P. H. Baylis
Abstract
A new extremely sensitive radioimmunoassay to measure plasma AVP has been developed. Antiserum to AVP of high affinity (Keq = 1.1 X 10(12) 1/mol), raised in rabbits, showed little cross-reaction with related analogues (LVP less than 0.03%, AVT, DDAVP, OXT less than 0.01). The specific activity of 125I-AVP (chloramine T method) was 1400-1750 Ci/mmol. The limit of detection of plasma AVP, after extraction of 2 ml plasma with Florisil, was 0.3 pmol/1. Coefficient of variations of plasma control (2 pmo1/1) were 9.7% (intraassay) and 15.3% (inter-assay), n = 15. Osmotic stimulation by hypertonic saline infusion caused a linear response in plasma AVP in normal subjects, but plasma AVP remained undetectable in patients with cranial diabetes insipidus. Suppression of AVP secretion by a standard oral water load and by alcohol and fluid in volunteers produced low or undetectable values of plasma AVP. In a patient with the syndrome of inappropriate antidiuresis, plasma AVP concentration was grossly elevated.
OpenAlex reports 114 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new extremely sensitive radioimmunoassay to measure plasma AVP has been developed. Antiserum to AVP of high affinity (Keq = 1.1 X 10(12) 1/mol), raised in rabbits, showed little cross-reaction with related analogues (LVP less than 0.03%, AVT, DDAVP, OXT less than 0.01). The specific activity of 125I-AVP (chloramine T method) was 1400-1750 Ci/mmol. The limit of detection of plasma AVP, after extraction of 2 ml plasma with Florisil, was 0.3 pmol/1. Coefficient of variations of plasma control (2 pmo1/1) were 9.7% (intraassay) and 15.3% (inter-assay), n = 15. Osmotic stimulation by hypertonic saline infusion caused a linear response in plasma AVP in normal subjects, but plasma AVP remained undetectable in patients with cranial diabetes insipidus. Suppression of AVP secretion by a standard oral water load and by alcohol and fluid in volunteers produced low or undetectable values of plasma AVP. In a patient with the syndrome of inappropriate antidiuresis, plasma AVP concentration was grossly elevated.
Key concepts: Radioimmunoassay, Vasopressin, Arginine, Chemistry, Internal medicine, Endocrinology, Chromatography, Biology