1998•Journal of Vascular and Interventional RadiologyOpen access

Replacement of Failing Tunneled Hemodialysis Catheters through Pre-existing Subcutaneous Tunnels: A Comparison of Catheter Function and Infection Rates for De Novo Placements and Over-the-Wire Exchanges

Richard Duszak, Ziv J. Haskal, Charlotte Thomas‐Hawkins, Michael C. Soulen, Richard A. Baum, Richard D. Shlansky-Goldberg, Constantin Cope

Open full text 93 citations

Abstract

PURPOSE: Tunneled hemodialysis catheter dysfunction often occurs from fibrin sheath formation. As a way to preserve existing catheter venous access sites, the authors evaluated over-the-wire exchange of catheters through pre-existing subcutaneous tunnels as an alternative to catheter removal and de novo catheter replacement. PATIENTS AND METHODS: One hundred nineteen catheters were placed in 68 patients. Seventy-seven catheters were placed de novo and 42 catheters were placed through the pre-existing subcutaneous tunnels of failing catheters. Technical success, short-term complications, infection rates, and functional catheter longevity were evaluated. RESULTS: Technical success for catheter exchange was 93%. Infection rates were comparable to those of de novo catheter placement: 0.15 and 0.11 infections per 100 catheter days for de novo and exchanged catheters, respectively. Catheter duration of function was not significantly different for de novo versus exchanged catheters: 63% and 51% at 3 months, 51% and 37% at 6 months, and 35% and 30% at 12 months, respectively. CONCLUSIONS: Over-the-wire exchange of tunneled hemodialysis catheters is safe and easily performed. It causes no increase in infectious complications and provides similar catheter longevity to de novo catheter placement. The procedure is an important option for prolonging tunneled hemodialysis catheter access sites.

About this research paper

What this paper is about

PURPOSE: Tunneled hemodialysis catheter dysfunction often occurs from fibrin sheath formation. As a way to preserve existing catheter venous access sites, the authors evaluated over-the-wire exchange of catheters through pre-existing subcutaneous tunnels as an alternative to catheter removal and de novo catheter replacement. PATIENTS AND METHODS: One hundred nineteen catheters were placed in 68 patients. Seventy-seven catheters were placed de novo and 42 catheters were placed through the pre-existing subcutaneous tunnels of failing catheters. Technical success, short-term complications, infection rates, and functional catheter longevity were evaluated. RESULTS: Technical success for catheter exchange was 93%. Infection rates were comparable to those of de novo catheter placement: 0.15 and 0.11 infections per 100 catheter days for de novo and exchanged catheters, respectively. Catheter duration of function was not significantly different for de novo versus exchanged catheters: 63% and 51% at 3 months, 51% and 37% at 6 months, and 35% and 30% at 12 months, respectively. CONCLUSIONS: Over-the-wire exchange of tunneled hemodialysis catheters is safe and easily performed. It causes no increase in infectious complications and provides similar catheter longevity to de novo catheter placement. The procedure is an important option for prolonging tunneled hemodialysis catheter access sites.

Why it matters

OpenAlex reports 93 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: Tunneled hemodialysis catheter dysfunction often occurs from fibrin sheath formation. As a way to preserve existing catheter venous access sites, the authors evaluated over-the-wire exchange of catheters through pre-existing subcutaneous tunnels as an alternative to catheter removal and de novo catheter replacement. PATIENTS AND METHODS: One hundred nineteen catheters were placed in 68 patients. Seventy-seven catheters were placed de novo and 42 catheters were placed through the pre-existing subcutaneous tunnels of failing catheters. Technical success, short-term complications, infection rates, and functional catheter longevity were evaluated. RESULTS: Technical success for catheter exchange was 93%. Infection rates were comparable to those of de novo catheter placement: 0.15 and 0.11 infections per 100 catheter days for de novo and exchanged catheters, respectively. Catheter duration of function was not significantly different for de novo versus exchanged catheters: 63% and 51% at 3 months, 51% and 37% at 6 months, and 35% and 30% at 12 months, respectively. CONCLUSIONS: Over-the-wire exchange of tunneled hemodialysis catheters is safe and easily performed. It causes no increase in infectious complications and provides similar catheter longevity to de novo catheter placement. The procedure is an important option for prolonging tunneled hemodialysis catheter access sites.

Key concepts: Medicine, Catheter, Hemodialysis Catheter, Surgery, Hemodialysis, Dialysis catheter

Related papers

Back to paper searchBrowse research topicsOriginal source
Replacement of Failing Tunneled Hemodialysis Catheters through Pre-existing Subcutaneous Tunnels: A Comparison of Catheter Function and Infection Rates for De Novo Placements and Over-the-Wire Exchanges — Research Paper | ScholarLens