2014IEEE Transactions on Plasma ScienceRequires access

Numerical Investigation of the Relativistic Magnetron Using a Novel Semitransparent Cathode

Wenyuan Yang, Zhiwei Dong, Yulin Yang, Ye Dong

Open publisher page 10 citations

Abstract

A semitransparent cathode is proposed for an efficient operation of the relativistic magnetron (RM) with axial extraction. The semitransparent cathode is a kind of shaped cathode. It is achieved using a cylindrical cathode with longitudinal strips removed. The cross section of each removed strip is fan-shaped and all the emit strips are connected in the central area of the cathode. Results of the 3-D particle-in-cell simulations show that the using a semitransparent cathode yields similar performance benefits compared with that using the transparent cathode proposed by the University of New Mexico. Simulation results also show that output characteristics of the RM using the semitransparent cathode are insensitive to the depth and width of each cathode slot. Thus, the semitransparent cathode might be more robust for practical applications.

About this research paper

What this paper is about

A semitransparent cathode is proposed for an efficient operation of the relativistic magnetron (RM) with axial extraction. The semitransparent cathode is a kind of shaped cathode. It is achieved using a cylindrical cathode with longitudinal strips removed. The cross section of each removed strip is fan-shaped and all the emit strips are connected in the central area of the cathode. Results of the 3-D particle-in-cell simulations show that the using a semitransparent cathode yields similar performance benefits compared with that using the transparent cathode proposed by the University of New Mexico. Simulation results also show that output characteristics of the RM using the semitransparent cathode are insensitive to the depth and width of each cathode slot. Thus, the semitransparent cathode might be more robust for practical applications.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A semitransparent cathode is proposed for an efficient operation of the relativistic magnetron (RM) with axial extraction. The semitransparent cathode is a kind of shaped cathode. It is achieved using a cylindrical cathode with longitudinal strips removed. The cross section of each removed strip is fan-shaped and all the emit strips are connected in the central area of the cathode. Results of the 3-D particle-in-cell simulations show that the using a semitransparent cathode yields similar performance benefits compared with that using the transparent cathode proposed by the University of New Mexico. Simulation results also show that output characteristics of the RM using the semitransparent cathode are insensitive to the depth and width of each cathode slot. Thus, the semitransparent cathode might be more robust for practical applications.

Key concepts: Cathode, STRIPS, Cavity magnetron, Materials science, Optics, Cold cathode, Optoelectronics, Hot cathode

Related papers

Back to paper searchBrowse research topicsOriginal source
Numerical Investigation of the Relativistic Magnetron Using a Novel Semitransparent Cathode — Research Paper | ScholarLens