An Improved Testing Protocol for Evaluating Anterior Spinal Instrumentation Using Graft Loads in a Single-Level Cervical Discectomy or Corpectomy Model

Denis J. DiAngelo, Geza Osztheimer, Kevin T. Foley

Open publisher page 0 citations

Abstract

Anterior cervical instrumentation used in discectomy or corpectomy graft fusion should restore the mechanical integrity of the operated spine and decrease graft complications. For fusion to occur, the spinal instrumentation must load-share with the interbody graft. Recent design changes in anterior cervical plates (ACP) aim to allow motion across the fusion site and load share with the graft [1]. However, existing American Society for Testing and Materials (ASTM) standards (F1717-96) for static and fatigue testing of spinal implant constructs in a corpectomy model do not include an interbody graft in the test method [2]. The objective of this study was to develop a non-destructive testing protocol and apparatus to rank the static and low-endurance performance of ACP instrumentation in single-level discectomy and corpectomy graft-plate models.

About this research paper

What this paper is about

Anterior cervical instrumentation used in discectomy or corpectomy graft fusion should restore the mechanical integrity of the operated spine and decrease graft complications. For fusion to occur, the spinal instrumentation must load-share with the interbody graft. Recent design changes in anterior cervical plates (ACP) aim to allow motion across the fusion site and load share with the graft [1]. However, existing American Society for Testing and Materials (ASTM) standards (F1717-96) for static and fatigue testing of spinal implant constructs in a corpectomy model do not include an interbody graft in the test method [2]. The objective of this study was to develop a non-destructive testing protocol and apparatus to rank the static and low-endurance performance of ACP instrumentation in single-level discectomy and corpectomy graft-plate models.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Anterior cervical instrumentation used in discectomy or corpectomy graft fusion should restore the mechanical integrity of the operated spine and decrease graft complications. For fusion to occur, the spinal instrumentation must load-share with the interbody graft. Recent design changes in anterior cervical plates (ACP) aim to allow motion across the fusion site and load share with the graft [1]. However, existing American Society for Testing and Materials (ASTM) standards (F1717-96) for static and fatigue testing of spinal implant constructs in a corpectomy model do not include an interbody graft in the test method [2]. The objective of this study was to develop a non-destructive testing protocol and apparatus to rank the static and low-endurance performance of ACP instrumentation in single-level discectomy and corpectomy graft-plate models.

Key concepts: Corpectomy, Discectomy, Anterior cervical discectomy and fusion, Medicine, Instrumentation (computer programming), Spinal fusion, Implant, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
An Improved Testing Protocol for Evaluating Anterior Spinal Instrumentation Using Graft Loads in a Single-Level Cervical Discectomy or Corpectomy Model — Research Paper | ScholarLens