2010The Journal of Toxicological SciencesOpen access

Measurement of respiratory function using whole-body plethysmography in unanesthetized and unrestrained nonhuman primates

Hiromi Iizuka, Kazuaki Sasaki, Norio Odagiri, Mayumi Obo, Masakazu Imaizumi, Hiroshi Atai

Open full text 32 citations

Abstract

Extended term, continuous measurement and observation of drug responses were performed to examine the feasibility of a custom-made whole-body plethysmograph for measuring respiratory function in unanesthetized, unrestrained monkeys. Using this apparatus, respiratory function (respiration rate, tidal volume, and minute volume) was observed for 23 hr in unanesthetized, unrestrained cynomolgus monkeys (Macaca fascicularis). The respiration rate, tidal volume, and minute volume in the light period (7:00 to 19:00) reached approximately 30% to 50% higher values than in the dark period (19:00 to 7:00), thus clearly exhibiting circadian variation in the cynomolgus monkey respiratory functions. Administration of morphine (10 mg/kg, s.c.) resulted in sustained reduction in tidal volume and minute volume, and ketamine (30 mg/kg [sub-anesthetic dose], i.m.) also produced sustained reduction in respiration rate, tidal volume, and minute volume. With dimorpholamine (1 mg/kg, i.v.) or caffeine (10 mg/kg, s.c.), respiration rate, tidal volume, and minute volume increased. Physiological saline (1 ml/kg, s.c. and 0.1 ml/kg, i.v.) and chlorpromazine (10 mg/kg, s.c.) produced no clear-cut changes in respiration rate, tidal volume, or minute volume. From the above results, we conclude that our custom-made whole-body plethysmograph is useful for measuring respiratory function in unanesthetized and unrestrained monkeys.

Open-access reader

About this research paper

What this paper is about

Extended term, continuous measurement and observation of drug responses were performed to examine the feasibility of a custom-made whole-body plethysmograph for measuring respiratory function in unanesthetized, unrestrained monkeys. Using this apparatus, respiratory function (respiration rate, tidal volume, and minute volume) was observed for 23 hr in unanesthetized, unrestrained cynomolgus monkeys (Macaca fascicularis). The respiration rate, tidal volume, and minute volume in the light period (7:00 to 19:00) reached approximately 30% to 50% higher values than in the dark period (19:00 to 7:00), thus clearly exhibiting circadian variation in the cynomolgus monkey respiratory functions. Administration of morphine (10 mg/kg, s.c.) resulted in sustained reduction in tidal volume and minute volume, and ketamine (30 mg/kg [sub-anesthetic dose], i.m.) also produced sustained reduction in respiration rate, tidal volume, and minute volume. With dimorpholamine (1 mg/kg, i.v.) or caffeine (10 mg/kg, s.c.), respiration rate, tidal volume, and minute volume increased. Physiological saline (1 ml/kg, s.c. and 0.1 ml/kg, i.v.) and chlorpromazine (10 mg/kg, s.c.) produced no clear-cut changes in respiration rate, tidal volume, or minute volume. From the above results, we conclude that our custom-made whole-body plethysmograph is useful for measuring respiratory function in unanesthetized and unrestrained monkeys.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Extended term, continuous measurement and observation of drug responses were performed to examine the feasibility of a custom-made whole-body plethysmograph for measuring respiratory function in unanesthetized, unrestrained monkeys. Using this apparatus, respiratory function (respiration rate, tidal volume, and minute volume) was observed for 23 hr in unanesthetized, unrestrained cynomolgus monkeys (Macaca fascicularis). The respiration rate, tidal volume, and minute volume in the light period (7:00 to 19:00) reached approximately 30% to 50% higher values than in the dark period (19:00 to 7:00), thus clearly exhibiting circadian variation in the cynomolgus monkey respiratory functions. Administration of morphine (10 mg/kg, s.c.) resulted in sustained reduction in tidal volume and minute volume, and ketamine (30 mg/kg [sub-anesthetic dose], i.m.) also produced sustained reduction in respiration rate, tidal volume, and minute volume. With dimorpholamine (1 mg/kg, i.v.) or caffeine (10 mg/kg, s.c.), respiration rate, tidal volume, and minute volume increased. Physiological saline (1 ml/kg, s.c. and 0.1 ml/kg, i.v.) and chlorpromazine (10 mg/kg, s.c.) produced no clear-cut changes in respiration rate, tidal volume, or minute volume. From the above results, we conclude that our custom-made whole-body plethysmograph is useful for measuring respiratory function in unanesthetized and unrestrained monkeys.

Key concepts: Tidal volume, Respiration, Respiratory minute volume, Respiratory rate, Plethysmograph, Respiratory system, Anesthesia, Volume (thermodynamics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of respiratory function using whole-body plethysmography in unanesthetized and unrestrained nonhuman primates — Research Paper | ScholarLens