2002Applied SpectroscopyRequires access

Development of a New Measurement Unit (MilkSpec-1) for Rapid Determination of Fat, Lactose, and Protein in Raw Milk Using Near-Infrared Transmittance Spectroscopy

Young-Ah Woo, Yoko Terazawa, Jie Yu Chen, Chie Iyo, Fuminori Terada, Sumio Kawano

Open publisher page 43 citations

Abstract

A new measurement unit, the MilkSpec-1, has been developed to determine rapidly and nondestructively the content of fat, lactose, and protein in raw milk using near-infrared transmittance spectroscopy. The spectral range over 700 to 1100 nm was used. This unit was designed for general glass test tubes, 12 mm in diameter and 10 mL in volume. Al 2 O 3 with a thickness of 2.5 mm was found to be optimum as a reference for acquiring the milk spectrum for this measurement. The NIR transmittance spectra of milk were acquired from raw milk samples without homogenization. The calibration model was developed and predicted by using a partial least-squares (PLS) algorithm. In order to reduce the scattering effect due to fat globules and casein micelles in NIR transmittance spectra, multiplicative scatter correction (MSC) and/or second derivative treatment were performed. MSC treatment proved to be useful for the development of calibration models for fat and protein. This study resulted in low standard errors of prediction (SEP), with 0.06, 0.10, and 0.10% for fat, lactose, and protein, respectively. It is shown that accurate, rapid, and nondestructive determination of milk composition could be successfully performed by using the MilkSpec-1, presenting the potential use of this method for real-time on-line monitoring in a milking process.

About this research paper

What this paper is about

A new measurement unit, the MilkSpec-1, has been developed to determine rapidly and nondestructively the content of fat, lactose, and protein in raw milk using near-infrared transmittance spectroscopy. The spectral range over 700 to 1100 nm was used. This unit was designed for general glass test tubes, 12 mm in diameter and 10 mL in volume. Al 2 O 3 with a thickness of 2.5 mm was found to be optimum as a reference for acquiring the milk spectrum for this measurement. The NIR transmittance spectra of milk were acquired from raw milk samples without homogenization. The calibration model was developed and predicted by using a partial least-squares (PLS) algorithm. In order to reduce the scattering effect due to fat globules and casein micelles in NIR transmittance spectra, multiplicative scatter correction (MSC) and/or second derivative treatment were performed. MSC treatment proved to be useful for the development of calibration models for fat and protein. This study resulted in low standard errors of prediction (SEP), with 0.06, 0.10, and 0.10% for fat, lactose, and protein, respectively. It is shown that accurate, rapid, and nondestructive determination of milk composition could be successfully performed by using the MilkSpec-1, presenting the potential use of this method for real-time on-line monitoring in a milking process.

Why it matters

OpenAlex reports 43 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new measurement unit, the MilkSpec-1, has been developed to determine rapidly and nondestructively the content of fat, lactose, and protein in raw milk using near-infrared transmittance spectroscopy. The spectral range over 700 to 1100 nm was used. This unit was designed for general glass test tubes, 12 mm in diameter and 10 mL in volume. Al 2 O 3 with a thickness of 2.5 mm was found to be optimum as a reference for acquiring the milk spectrum for this measurement. The NIR transmittance spectra of milk were acquired from raw milk samples without homogenization. The calibration model was developed and predicted by using a partial least-squares (PLS) algorithm. In order to reduce the scattering effect due to fat globules and casein micelles in NIR transmittance spectra, multiplicative scatter correction (MSC) and/or second derivative treatment were performed. MSC treatment proved to be useful for the development of calibration models for fat and protein. This study resulted in low standard errors of prediction (SEP), with 0.06, 0.10, and 0.10% for fat, lactose, and protein, respectively. It is shown that accurate, rapid, and nondestructive determination of milk composition could be successfully performed by using the MilkSpec-1, presenting the potential use of this method for real-time on-line monitoring in a milking process.

Key concepts: Lactose, Transmittance, Absorbance, Raw milk, Analytical Chemistry (journal), Chemistry, Casein, Spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of a New Measurement Unit (MilkSpec-1) for Rapid Determination of Fat, Lactose, and Protein in Raw Milk Using Near-Infrared Transmittance Spectroscopy — Research Paper | ScholarLens