1986Journal of Analytical Atomic SpectrometryRequires access

Determination of arsenic and antimony by hydride generation atomic absorption spectrometry using a small hydride generator

Ping-Kay Hon, Oi‐Wah Lau, Shu‐Ki Tsui

Open publisher page 22 citations

Abstract

A sensitive method for the determination of arsenic and antimony by hydride generation atomic absorption spectrometry, using a glass vial (internal volume, 8.6 ml) as the hydride generator, is described. The optimum flow-rate of the carrier gas was 0.2 l min–1 and the hydrochloric acid concentration used was 0.25 M. The absolute sensitivities were 0.06 and 0.10 ng for arsenic and antimony, respectively. The relative standard deviations were around 2% for both elements. A masking solution consisting of thiourea and ascorbic acid proved to be effective for suppressing the effect of a number of interferents. The accuracy of the proposed method was checked by determining the contents of arsenic and antimony in two standard reference materials.

About this research paper

What this paper is about

A sensitive method for the determination of arsenic and antimony by hydride generation atomic absorption spectrometry, using a glass vial (internal volume, 8.6 ml) as the hydride generator, is described. The optimum flow-rate of the carrier gas was 0.2 l min–1 and the hydrochloric acid concentration used was 0.25 M. The absolute sensitivities were 0.06 and 0.10 ng for arsenic and antimony, respectively. The relative standard deviations were around 2% for both elements. A masking solution consisting of thiourea and ascorbic acid proved to be effective for suppressing the effect of a number of interferents. The accuracy of the proposed method was checked by determining the contents of arsenic and antimony in two standard reference materials.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A sensitive method for the determination of arsenic and antimony by hydride generation atomic absorption spectrometry, using a glass vial (internal volume, 8.6 ml) as the hydride generator, is described. The optimum flow-rate of the carrier gas was 0.2 l min–1 and the hydrochloric acid concentration used was 0.25 M. The absolute sensitivities were 0.06 and 0.10 ng for arsenic and antimony, respectively. The relative standard deviations were around 2% for both elements. A masking solution consisting of thiourea and ascorbic acid proved to be effective for suppressing the effect of a number of interferents. The accuracy of the proposed method was checked by determining the contents of arsenic and antimony in two standard reference materials.

Key concepts: Hydride, Antimony, Arsenic, Chemistry, Atomic absorption spectroscopy, Hydrochloric acid, Thiourea, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of arsenic and antimony by hydride generation atomic absorption spectrometry using a small hydride generator — Research Paper | ScholarLens