Chromaticity Limitations of the Best Physically Realizable Three-Filter Photoelectric Colorimeter

Johannes A. Van den Akker

Open publisher page 12 citations

Abstract

The theoretical requirements to be met by a photoelectric colorimeter capable of yielding I.C.I, tristimulus values, and relationships between tristimulus values and instrumental reflectances are given. For practical reasons, the correct photoelectric colorimeter must be equipped with four filters. It is commonly believed that a three-filter photoelectric colorimeter would be generally suitable for color specification and color matching; this is tested from the theoretical standpoint, and it is shown that the best physically realizable three-filter photoelectric colorimeter would suffer a fundamental chromaticity limitation. Relationships between the displacements of instrumental points on the chromaticity diagram and errors in the “red,” green, and blue reflectances are given. Especial attention is given to errors originating in the assumption that the blue reflectance may be used in the evaluation of both the X and Z tristimulus values; maximal displacements associated with this assumption are given for a number of points on the diagram, and it is shown that actual chromaticity errors would be objectionably great for many colors of importance. The use of a three-filter photoelectric colorimeter as a color comparator is discussed.

About this research paper

What this paper is about

The theoretical requirements to be met by a photoelectric colorimeter capable of yielding I.C.I, tristimulus values, and relationships between tristimulus values and instrumental reflectances are given. For practical reasons, the correct photoelectric colorimeter must be equipped with four filters. It is commonly believed that a three-filter photoelectric colorimeter would be generally suitable for color specification and color matching; this is tested from the theoretical standpoint, and it is shown that the best physically realizable three-filter photoelectric colorimeter would suffer a fundamental chromaticity limitation. Relationships between the displacements of instrumental points on the chromaticity diagram and errors in the “red,” green, and blue reflectances are given. Especial attention is given to errors originating in the assumption that the blue reflectance may be used in the evaluation of both the X and Z tristimulus values; maximal displacements associated with this assumption are given for a number of points on the diagram, and it is shown that actual chromaticity errors would be objectionably great for many colors of importance. The use of a three-filter photoelectric colorimeter as a color comparator is discussed.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The theoretical requirements to be met by a photoelectric colorimeter capable of yielding I.C.I, tristimulus values, and relationships between tristimulus values and instrumental reflectances are given. For practical reasons, the correct photoelectric colorimeter must be equipped with four filters. It is commonly believed that a three-filter photoelectric colorimeter would be generally suitable for color specification and color matching; this is tested from the theoretical standpoint, and it is shown that the best physically realizable three-filter photoelectric colorimeter would suffer a fundamental chromaticity limitation. Relationships between the displacements of instrumental points on the chromaticity diagram and errors in the “red,” green, and blue reflectances are given. Especial attention is given to errors originating in the assumption that the blue reflectance may be used in the evaluation of both the X and Z tristimulus values; maximal displacements associated with this assumption are given for a number of points on the diagram, and it is shown that actual chromaticity errors would be objectionably great for many colors of importance. The use of a three-filter photoelectric colorimeter as a color comparator is discussed.

Key concepts: Colorimeter, Chromaticity, Photoelectric effect, Optics, Diagram, Colorimetry, Filter (signal processing), Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Chromaticity Limitations of the Best Physically Realizable Three-Filter Photoelectric Colorimeter — Research Paper | ScholarLens