2010•Journal of Saudi Chemical SocietyOpen access

Extractive-spectrophotometric methods for determination of anti-Parkinsonian drug in pharmaceutical formulations and in biological samples using sulphonphthalein acid dyes

Hany A. Omara, Alaa S. Amin

Open full text 17 citations

Abstract

Abstract A simple, accurate and highly sensitive spectrophotometric methods are proposed for the rapid and accurate determination of amantadine HCl (AMD) using bromocressol green (BCG), bromophenol blue (BPB) and bromothymol blue (BTB). The developed methods involve formation of stable yellow colored chloroform extractable ion-associate complexes of the amino derivative (basic nitrogen) of the AMD with three sulphonphthalein acid dyes, namely; BCG, BPB and BTB, in acidic medium. The ion-associates exhibit absorption maxima at 415, 412 and 414 nm for BCG, BPB and BTB, respectively. AMD can be determined up to 1.5–16.5, 1.4–14.0 and 1.6–17 μg mL −1 , respectively. The effect of optimum conditions via acidity, reagent concentration, time, and solvent was studied. The stoichiometry of the reaction was found to be 1:1 in all cases. The low relative standard deviation values indicate good precision and high recovery values. These methods have been successfully applied for the assay of AMD in pharmaceutical formulations. Statistical comparison of the results with the reference method shows excellent agreement and indicates no significant difference in accuracy and precision.

About this research paper

What this paper is about

Abstract A simple, accurate and highly sensitive spectrophotometric methods are proposed for the rapid and accurate determination of amantadine HCl (AMD) using bromocressol green (BCG), bromophenol blue (BPB) and bromothymol blue (BTB). The developed methods involve formation of stable yellow colored chloroform extractable ion-associate complexes of the amino derivative (basic nitrogen) of the AMD with three sulphonphthalein acid dyes, namely; BCG, BPB and BTB, in acidic medium. The ion-associates exhibit absorption maxima at 415, 412 and 414 nm for BCG, BPB and BTB, respectively. AMD can be determined up to 1.5–16.5, 1.4–14.0 and 1.6–17 μg mL −1 , respectively. The effect of optimum conditions via acidity, reagent concentration, time, and solvent was studied. The stoichiometry of the reaction was found to be 1:1 in all cases. The low relative standard deviation values indicate good precision and high recovery values. These methods have been successfully applied for the assay of AMD in pharmaceutical formulations. Statistical comparison of the results with the reference method shows excellent agreement and indicates no significant difference in accuracy and precision.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract A simple, accurate and highly sensitive spectrophotometric methods are proposed for the rapid and accurate determination of amantadine HCl (AMD) using bromocressol green (BCG), bromophenol blue (BPB) and bromothymol blue (BTB). The developed methods involve formation of stable yellow colored chloroform extractable ion-associate complexes of the amino derivative (basic nitrogen) of the AMD with three sulphonphthalein acid dyes, namely; BCG, BPB and BTB, in acidic medium. The ion-associates exhibit absorption maxima at 415, 412 and 414 nm for BCG, BPB and BTB, respectively. AMD can be determined up to 1.5–16.5, 1.4–14.0 and 1.6–17 μg mL −1 , respectively. The effect of optimum conditions via acidity, reagent concentration, time, and solvent was studied. The stoichiometry of the reaction was found to be 1:1 in all cases. The low relative standard deviation values indicate good precision and high recovery values. These methods have been successfully applied for the assay of AMD in pharmaceutical formulations. Statistical comparison of the results with the reference method shows excellent agreement and indicates no significant difference in accuracy and precision.

Key concepts: Bromothymol blue, Bromophenol blue, Chemistry, Reagent, Chloroform, Chromatography, Solvent, Acid dye

Related papers

Back to paper searchBrowse research topicsOriginal source
Extractive-spectrophotometric methods for determination of anti-Parkinsonian drug in pharmaceutical formulations and in biological samples using sulphonphthalein acid dyes — Research Paper | ScholarLens