Application of Elimination Voltammetry to Adsorptive Stripping of DNA
Libuše Trnková, René Kizek, O. Dračka
Abstract
Libuše Trnková, René Kizek, O. Dračka
Abstract
Adsorptive stripping voltammetry has been extended by elimination voltammetry with linear scan rate (EVLS). EVLS offers the elimination of selected currents from the linear scan voltammetry results. It can be achieved by an elimination function formed by a linear combination of total currents measured at different scan rates, because the basic idea of elimination of chosen currents (for example the charging current, Ic, the reversible current for substances transported only by linear diffusion, Ir, and the purely kinetic current, Ik) consists of the different dependence of voltammetric current on the scan rate. In this article, the problem of substance adsorption influence on the elimination voltammetry results has been studied. Theoretical curves of an irreversible current with adsorbed substance being electroactive were calculated for three elimination functions. A: the function eliminating Ik and Ic and conserving Ir B: the function eliminating Ic and Ir, conserving Ik; and C: the function eliminating Ir and Ik and conserving Ic, where Ic, Ir, and Ik are the charging current, the reversible diffusion current, and the kinetic current, respectively. A larger difference between diffusion and adsorption was exhibited by the elimination function A. It provides a substantial increase in resolution and sensitivity as compared to the linear scan voltammetry current peak and clearly marks the adsorption. In case of the adsorption of electroactive substances this elimination function A can be useful for analytical applications, particularly for the adsorptive stripping voltammetry with electrochemical irreversible systems. As a practical application, the adsorptive stripping voltammetry of thermally denatured DNA on a hanging mercury electrode has been developed. While the LSV signal of single-stranded DNA at low concentrations gives a slight hint of the cathodic peak (due to the reduction of adenine and cytosine residues), the elimination A provides quite a clear signal in the form of the peak-counterpeak. It is possible to determinate DNA at concentrations below micrograms per milliliter by using this elimination function. The results received by the adsorptive stripping voltammetry in the mode of linear scan (LSV), square-wave (SWV) and elimination with linear scan (EVLS) are discussed.
OpenAlex reports 83 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Adsorptive stripping voltammetry has been extended by elimination voltammetry with linear scan rate (EVLS). EVLS offers the elimination of selected currents from the linear scan voltammetry results. It can be achieved by an elimination function formed by a linear combination of total currents measured at different scan rates, because the basic idea of elimination of chosen currents (for example the charging current, Ic, the reversible current for substances transported only by linear diffusion, Ir, and the purely kinetic current, Ik) consists of the different dependence of voltammetric current on the scan rate. In this article, the problem of substance adsorption influence on the elimination voltammetry results has been studied. Theoretical curves of an irreversible current with adsorbed substance being electroactive were calculated for three elimination functions. A: the function eliminating Ik and Ic and conserving Ir B: the function eliminating Ic and Ir, conserving Ik; and C: the function eliminating Ir and Ik and conserving Ic, where Ic, Ir, and Ik are the charging current, the reversible diffusion current, and the kinetic current, respectively. A larger difference between diffusion and adsorption was exhibited by the elimination function A. It provides a substantial increase in resolution and sensitivity as compared to the linear scan voltammetry current peak and clearly marks the adsorption. In case of the adsorption of electroactive substances this elimination function A can be useful for analytical applications, particularly for the adsorptive stripping voltammetry with electrochemical irreversible systems. As a practical application, the adsorptive stripping voltammetry of thermally denatured DNA on a hanging mercury electrode has been developed. While the LSV signal of single-stranded DNA at low concentrations gives a slight hint of the cathodic peak (due to the reduction of adenine and cytosine residues), the elimination A provides quite a clear signal in the form of the peak-counterpeak. It is possible to determinate DNA at concentrations below micrograms per milliliter by using this elimination function. The results received by the adsorptive stripping voltammetry in the mode of linear scan (LSV), square-wave (SWV) and elimination with linear scan (EVLS) are discussed.
Key concepts: Voltammetry, Horizontal scan rate, Adsorptive stripping voltammetry, Cyclic voltammetry, Chemistry, Adsorption, Analytical Chemistry (journal), Linear sweep voltammetry