Liquid Chromatographic Validation of a Quantitation Method for Phytoestrogens, Biochanin‐A, Coumestrol, Daidzein, Formononetin, and Genistein, in Lucerne
Luísa Ma Martin, Ma. Conceição Castilho, M.I.N. Silveira, José Mário Girão Abreu
Abstract
Luísa Ma Martin, Ma. Conceição Castilho, M.I.N. Silveira, José Mário Girão Abreu
Abstract
A methodology was validated to evaluate biochanin‐A, coumestrol, daidzein, formononetin, and genistein in lucerne (Medicago sativa). Extraction done through acid hydrolysis at 80°C, followed by extraction with HLB cartridges. A C18 column (4.6×250 mm) with a 0.8 mL/min flow of methanol solution (isocratic) and detection at 260 nm was applied. Separation factors were greater than 1.1 and resolutions were superior to 2.4. Linearity was established and correlation coefficients of responses were greater than 0.995. The detection and quantification limits were between 0.12–0.17 µg · mL−1 and 0.37–0.53 µg · mL−1, respectively. The coefficients of variation were between 5 and 15%. The accurate results in lucerne were 78, 35, 20, 14, and 11 mg (kgDM)−1 for coumestrol, formononetin, daidzein, genistein, and biochanin‐A.
OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A methodology was validated to evaluate biochanin‐A, coumestrol, daidzein, formononetin, and genistein in lucerne (Medicago sativa). Extraction done through acid hydrolysis at 80°C, followed by extraction with HLB cartridges. A C18 column (4.6×250 mm) with a 0.8 mL/min flow of methanol solution (isocratic) and detection at 260 nm was applied. Separation factors were greater than 1.1 and resolutions were superior to 2.4. Linearity was established and correlation coefficients of responses were greater than 0.995. The detection and quantification limits were between 0.12–0.17 µg · mL−1 and 0.37–0.53 µg · mL−1, respectively. The coefficients of variation were between 5 and 15%. The accurate results in lucerne were 78, 35, 20, 14, and 11 mg (kgDM)−1 for coumestrol, formononetin, daidzein, genistein, and biochanin‐A.
Key concepts: Formononetin, Daidzein, Biochanin A, Coumestrol, Genistein, Chromatography, Chemistry, Extraction (chemistry)