2014Unpublished venueRequires access

High power hybrid contactor for electrical test application

Rajesh Kumar Panda, Jitendar Veeramalla

Open publisher page 1 citations

Abstract

It's been a practice to use a back up contactor in addition to master contactor to evaluate the electrical life of the test contactor for AC-3 utilisation category. It is expected that the life of the test contactor is in few millions, which the back - up contactor may not be able to support as during each make - break operation there is heavy erosion of contact material due to arcing. It demands frequent maintenance or even replacement of the back - up contactor to complete the AC-3 electrical life test. The paper reveals about the development of a test set up to perform AC-3 electrical life test upon the test contactor using a high power hybrid back up contactor which will provide millions of arc less switching. At the outset it explains about the control & power circuit and then discuss in detail about the prototype development and performance evaluation of the test set up done upon the test contactor. The test results reveal about arc less breaking operation of the hybrid contactor at 415V, 2.1kA, 50Hz, 0.35 power factors with no pit marks, crater formation and contact erosion. It is expected to complete millions of operations.

About this research paper

What this paper is about

It's been a practice to use a back up contactor in addition to master contactor to evaluate the electrical life of the test contactor for AC-3 utilisation category. It is expected that the life of the test contactor is in few millions, which the back - up contactor may not be able to support as during each make - break operation there is heavy erosion of contact material due to arcing. It demands frequent maintenance or even replacement of the back - up contactor to complete the AC-3 electrical life test. The paper reveals about the development of a test set up to perform AC-3 electrical life test upon the test contactor using a high power hybrid back up contactor which will provide millions of arc less switching. At the outset it explains about the control & power circuit and then discuss in detail about the prototype development and performance evaluation of the test set up done upon the test contactor. The test results reveal about arc less breaking operation of the hybrid contactor at 415V, 2.1kA, 50Hz, 0.35 power factors with no pit marks, crater formation and contact erosion. It is expected to complete millions of operations.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It's been a practice to use a back up contactor in addition to master contactor to evaluate the electrical life of the test contactor for AC-3 utilisation category. It is expected that the life of the test contactor is in few millions, which the back - up contactor may not be able to support as during each make - break operation there is heavy erosion of contact material due to arcing. It demands frequent maintenance or even replacement of the back - up contactor to complete the AC-3 electrical life test. The paper reveals about the development of a test set up to perform AC-3 electrical life test upon the test contactor using a high power hybrid back up contactor which will provide millions of arc less switching. At the outset it explains about the control & power circuit and then discuss in detail about the prototype development and performance evaluation of the test set up done upon the test contactor. The test results reveal about arc less breaking operation of the hybrid contactor at 415V, 2.1kA, 50Hz, 0.35 power factors with no pit marks, crater formation and contact erosion. It is expected to complete millions of operations.

Key concepts: Contactor, Electric arc, Power (physics), Automotive engineering, Computer science, Engineering, Electrical engineering, Quantum mechanics