2013•Orthopedic ReviewsOpen access

Assessment of acetabulum anteversion aligned with the transverse acetabulum ligament: cadaveric study using image-free navigation system

Tomokazu Fukui, Shigeo Fukunishi, Shoji Nishio, Yuki Fujihara, Shohei Okahisa, Shinichi Yoshiya

Open full text 9 citations

Abstract

The transverse acetabulum ligament (TAL) has been used as an intraoperative anatomical landmark to position the acetabulum cup in total hip arthroplasty (THA). However, the validity of the use of TAL has not been clarified. The purpose of this study was to examine the orientation of the cup component aligned with the TAL in cadaveric study. The 31 hips in 25 whole-body embalmed cadavers were examined. The donors were 12 men and 13 women. Simulated THA procedure using image-free navigation system was performed and a trial cup with a diameter of approximately 2 mm less than the size of the acetabulum were inserted and snugly fitted on the TAL through the posterior wall of acetabulum. The orientation of the cup component was measured using an image-free THA navigation system. The measured radiographic anteversion and inclination angles averaged 18.2±7.2° (range: 2.0-33.2°) and 43.5±4.2° (range: 33.1-51.0°) respectively. Based on the Lewinnek's safe zone criteria, 26 hips (80.6%) were judged to be within the. Moreover, in the analysis of the gender difference of TAL angles, the average anteversion angle was shown to be significant larger in female than male population. The TAL can be effectively used an intraoperative landmark to align the acetabulum component helping reduce the risk of dislocation after surgery. In the intraoperative judgment, a gender difference in the alignment of the TAL should be taken into consideration.

About this research paper

What this paper is about

The transverse acetabulum ligament (TAL) has been used as an intraoperative anatomical landmark to position the acetabulum cup in total hip arthroplasty (THA). However, the validity of the use of TAL has not been clarified. The purpose of this study was to examine the orientation of the cup component aligned with the TAL in cadaveric study. The 31 hips in 25 whole-body embalmed cadavers were examined. The donors were 12 men and 13 women. Simulated THA procedure using image-free navigation system was performed and a trial cup with a diameter of approximately 2 mm less than the size of the acetabulum were inserted and snugly fitted on the TAL through the posterior wall of acetabulum. The orientation of the cup component was measured using an image-free THA navigation system. The measured radiographic anteversion and inclination angles averaged 18.2±7.2° (range: 2.0-33.2°) and 43.5±4.2° (range: 33.1-51.0°) respectively. Based on the Lewinnek's safe zone criteria, 26 hips (80.6%) were judged to be within the. Moreover, in the analysis of the gender difference of TAL angles, the average anteversion angle was shown to be significant larger in female than male population. The TAL can be effectively used an intraoperative landmark to align the acetabulum component helping reduce the risk of dislocation after surgery. In the intraoperative judgment, a gender difference in the alignment of the TAL should be taken into consideration.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The transverse acetabulum ligament (TAL) has been used as an intraoperative anatomical landmark to position the acetabulum cup in total hip arthroplasty (THA). However, the validity of the use of TAL has not been clarified. The purpose of this study was to examine the orientation of the cup component aligned with the TAL in cadaveric study. The 31 hips in 25 whole-body embalmed cadavers were examined. The donors were 12 men and 13 women. Simulated THA procedure using image-free navigation system was performed and a trial cup with a diameter of approximately 2 mm less than the size of the acetabulum were inserted and snugly fitted on the TAL through the posterior wall of acetabulum. The orientation of the cup component was measured using an image-free THA navigation system. The measured radiographic anteversion and inclination angles averaged 18.2±7.2° (range: 2.0-33.2°) and 43.5±4.2° (range: 33.1-51.0°) respectively. Based on the Lewinnek's safe zone criteria, 26 hips (80.6%) were judged to be within the. Moreover, in the analysis of the gender difference of TAL angles, the average anteversion angle was shown to be significant larger in female than male population. The TAL can be effectively used an intraoperative landmark to align the acetabulum component helping reduce the risk of dislocation after surgery. In the intraoperative judgment, a gender difference in the alignment of the TAL should be taken into consideration.

Key concepts: Acetabulum, Cadaveric spasm, Cadaver, Medicine, Anatomical landmark, Anatomy, Ligament, Landmark

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of acetabulum anteversion aligned with the transverse acetabulum ligament: cadaveric study using image-free navigation system — Research Paper | ScholarLens