2004Journal of Applied Polymer ScienceRequires access

Comparison of maleic anhydride grafting onto powder and granular polypropylene in the melt by reactive extrusion

Yılser Güldoğan, Sinan Eğri, Zakır M. O. Rzaev, Erhan Pişkın

Open publisher page 73 citations

Abstract

Abstract The grafting of powder and granular polypropylene (PP) with maleic anhydride (MA) was investigated in a reactive extrusion process with dicumyl peroxide (DCP) as an initiator. The effects of the MA and DCP contents in the feed on grafting were investigated. Under the experimental conditions applied in this study, the grafted monomer unit content was varied from 0.023 to 0.5%. The MA grafting efficiency of powder PP was higher than that obtained for the granular form of PP. In general, the grafting degree first increased with the MA or DCP content in the feed, then reached a maximum value, and finally decreased because of several possible alternative reactions during the grafting. The grafting of powder PP was more successful because of better initial mixing and less diffusional resistance during the grafting. An increase in the MA content in the feed caused significant reductions in the melt‐flow index of the graft copolymers. The results obtained with Fourier transform infrared, differential scanning calorimetry, and X‐ray powder diffraction analyses indicated that the structure, macrotacticity, crystallinity, crystallization, and thermal behavior of PP changed with grafting and depended on the grafting degree. © 2004 Wiley Periodicals, Inc. J Appl Polym Sci 92: 3675–3684, 2004

About this research paper

What this paper is about

Abstract The grafting of powder and granular polypropylene (PP) with maleic anhydride (MA) was investigated in a reactive extrusion process with dicumyl peroxide (DCP) as an initiator. The effects of the MA and DCP contents in the feed on grafting were investigated. Under the experimental conditions applied in this study, the grafted monomer unit content was varied from 0.023 to 0.5%. The MA grafting efficiency of powder PP was higher than that obtained for the granular form of PP. In general, the grafting degree first increased with the MA or DCP content in the feed, then reached a maximum value, and finally decreased because of several possible alternative reactions during the grafting. The grafting of powder PP was more successful because of better initial mixing and less diffusional resistance during the grafting. An increase in the MA content in the feed caused significant reductions in the melt‐flow index of the graft copolymers. The results obtained with Fourier transform infrared, differential scanning calorimetry, and X‐ray powder diffraction analyses indicated that the structure, macrotacticity, crystallinity, crystallization, and thermal behavior of PP changed with grafting and depended on the grafting degree. © 2004 Wiley Periodicals, Inc. J Appl Polym Sci 92: 3675–3684, 2004

Why it matters

OpenAlex reports 73 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The grafting of powder and granular polypropylene (PP) with maleic anhydride (MA) was investigated in a reactive extrusion process with dicumyl peroxide (DCP) as an initiator. The effects of the MA and DCP contents in the feed on grafting were investigated. Under the experimental conditions applied in this study, the grafted monomer unit content was varied from 0.023 to 0.5%. The MA grafting efficiency of powder PP was higher than that obtained for the granular form of PP. In general, the grafting degree first increased with the MA or DCP content in the feed, then reached a maximum value, and finally decreased because of several possible alternative reactions during the grafting. The grafting of powder PP was more successful because of better initial mixing and less diffusional resistance during the grafting. An increase in the MA content in the feed caused significant reductions in the melt‐flow index of the graft copolymers. The results obtained with Fourier transform infrared, differential scanning calorimetry, and X‐ray powder diffraction analyses indicated that the structure, macrotacticity, crystallinity, crystallization, and thermal behavior of PP changed with grafting and depended on the grafting degree. © 2004 Wiley Periodicals, Inc. J Appl Polym Sci 92: 3675–3684, 2004

Key concepts: Maleic anhydride, Grafting, Reactive extrusion, Polypropylene, Materials science, Crystallinity, Differential scanning calorimetry, Melt flow index

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of maleic anhydride grafting onto powder and granular polypropylene in the melt by reactive extrusion — Research Paper | ScholarLens